Skip to content

Supported Inputs

Built-In Inputs (System)~

AoT: AoT Version~

  • Manufacturer: AoT
  • Measurements: Version as Major.Minor.Revision
OptionTypeDescription
Measurements EnabledMulti-SelectThe measurements to record
Period (Seconds)DecimalThe duration between measurements or actions

AoT: CPU Load~

  • Manufacturer: AoT
  • Measurements: CPULoad
  • Libraries: os.getloadavg()
OptionTypeDescription
Measurements EnabledMulti-SelectThe measurements to record
Period (Seconds)DecimalThe duration between measurements or actions

AoT: Free Space~

  • Manufacturer: AoT
  • Measurements: Unallocated Disk Space
  • Libraries: os.statvfs()
OptionTypeDescription
Period (Seconds)DecimalThe duration between measurements or actions

AoT: Output State (On/Off)~

  • Manufacturer: AoT
  • Measurements: Boolean

This Input stores a 0 (off) or 1 (on) for the selected On/Off Output.

OptionTypeDescription
Period (Seconds)DecimalThe duration between measurements or actions
On/Off Output ChannelSelect Channel (Output_Channels)Select an output to measure

AoT: Server Ping~

  • Manufacturer: AoT
  • Measurements: Boolean
  • Libraries: ping

This Input executes the bash command "ping -c [times] -w [deadline] [host]" to determine if the host can be pinged.

OptionTypeDescription
Period (Seconds)DecimalThe duration between measurements or actions
Pre OutputSelectTurn the selected output on before taking every measurement
Pre Out Duration (Seconds)DecimalIf a Pre Output is selected, set the duration to turn the Pre Output on for before every measurement is acquired.
Pre During MeasureBooleanCheck to turn the output off after (opposed to before) the measurement is complete

AoT: Server Port Open~

  • Manufacturer: AoT
  • Measurements: Boolean
  • Libraries: nc

This Input executes the bash command "nc -zv [host] [port]" to determine if the host at a particular port is accessible.

OptionTypeDescription
Period (Seconds)DecimalThe duration between measurements or actions
Pre OutputSelectTurn the selected output on before taking every measurement
Pre Out Duration (Seconds)DecimalIf a Pre Output is selected, set the duration to turn the Pre Output on for before every measurement is acquired.
Pre During MeasureBooleanCheck to turn the output off after (opposed to before) the measurement is complete

AoT: Spacer~

  • Manufacturer: AoT

A spacer to organize Inputs.

OptionTypeDescription
ColorText - Default Value: #000000The color of the name text

AoT: System and AoT RAM~

  • Manufacturer: AoT
  • Measurements: RAM Allocation
  • Libraries: psutil, resource.getrusage()
  • Dependencies: psutil
OptionTypeDescription
Measurements EnabledMulti-SelectThe measurements to record
Period (Seconds)DecimalThe duration between measurements or actions
AoT Frontend RAM EndpointText - Default Value: https://127.0.0.1/ramThe endpoint to get AoT frontend ram usage

AoT: Test Input: Save your own measurement value~

  • Manufacturer: AoT
  • Measurements: Variable measurements

This is a simple test Input that allows you to save any value as a measurement, that will be stored in the measurement database. It can be useful for testing other parts of AoT, such as PIDs, Bang-Bang, and Conditional Functions, since you can be completely in control of what values the input provides to the Functions. Note 1: Select and save the Name and Measurement Unit for each channel. Once the unit has been saved, you can convert to other units in the Convert Measurement section. Note 2: Activate the Input before storing measurements.

OptionTypeDescription
Measurements EnabledMulti-SelectThe measurements to record
Channel Options
NameTextA name to distinguish this from others
Commands
Enter the Value you want to store as a measurement, then press Store Measurement.
ChannelIntegerThis is the channel to save the measurement value to
ValueDecimal - Default Value: 10.0This is the measurement value to save for this Input
Store MeasurementButton

AoT: Uptime~

  • Manufacturer: AoT
  • Measurements: Seconds Since System Startup
OptionTypeDescription
Period (Seconds)DecimalThe duration between measurements or actions

Linux: Bash Command~

  • Manufacturer: Linux
  • Measurements: Return Value
  • Interfaces: AoT

This Input will execute a command in the shell and store the output as a float value. Perform any unit conversions within your script or command. A measurement/unit is required to be selected.

OptionTypeDescription
Period (Seconds)DecimalThe duration between measurements or actions
Pre OutputSelectTurn the selected output on before taking every measurement
Pre Out Duration (Seconds)DecimalIf a Pre Output is selected, set the duration to turn the Pre Output on for before every measurement is acquired.
Pre During MeasureBooleanCheck to turn the output off after (opposed to before) the measurement is complete
Command TimeoutInteger - Default Value: 60How long to wait for the command to finish before killing the process.
UserText - Default Value: aotThe user to execute the command
Current Working DirectoryText - Default Value: /home/piThe current working directory of the shell environment.

Linux: Python 3 Code (v1.0)~

  • Manufacturer: Linux
  • Measurements: Store Value(s)
  • Interfaces: AoT
  • Dependencies: pylint

All channels require a Measurement Unit to be selected and saved in order to store values to the database. Your code is executed from the same Python virtual environment that AoT runs from. Therefore, you must install Python libraries to this environment if you want them to be available to your code. This virtualenv is located at /opt/AoT/env and if you wanted to install a library, for example "my_library" using pip, you would execute "sudo /opt/AoT/env/bin/pip install my_library".

OptionTypeDescription
Measurements EnabledMulti-SelectThe measurements to record
Period (Seconds)DecimalThe duration between measurements or actions
Pre OutputSelectTurn the selected output on before taking every measurement
Pre Out Duration (Seconds)DecimalIf a Pre Output is selected, set the duration to turn the Pre Output on for before every measurement is acquired.
Pre During MeasureBooleanCheck to turn the output off after (opposed to before) the measurement is complete
Analyze Python Code with PylintBoolean - Default Value: TrueAnalyze your Python code with pylint when saving

Linux: Python 3 Code (v2.0)~

  • Manufacturer: Linux
  • Measurements: Store Value(s)
  • Interfaces: AoT
  • Dependencies: pylint

This is an alternate Python 3 Code Input that uses a different method for storing values to the database. This was created because the Python 3 Code v1.0 Input does not allow the use of Input Actions. This method does allow the use of Input Actions. (11/21/2023 Update: The Python 3 Code (v1.0) Input now allows the execution of Actions). All channels require a Measurement Unit to be selected and saved in order to store values to the database. Your code is executed from the same Python virtual environment that AoT runs from. Therefore, you must install Python libraries to this environment if you want them to be available to your code. This virtualenv is located at /opt/AoT/env and if you wanted to install a library, for example "my_library" using pip, you would execute "sudo /opt/AoT/env/bin/pip install my_library".

OptionTypeDescription
Measurements EnabledMulti-SelectThe measurements to record
Period (Seconds)DecimalThe duration between measurements or actions
Pre OutputSelectTurn the selected output on before taking every measurement
Pre Out Duration (Seconds)DecimalIf a Pre Output is selected, set the duration to turn the Pre Output on for before every measurement is acquired.
Pre During MeasureBooleanCheck to turn the output off after (opposed to before) the measurement is complete
Python 3 CodeThe code to execute. Must return a value.
Analyze Python Code with PylintBoolean - Default Value: TrueAnalyze your Python code with pylint when saving

Raspberry Pi: CPU/GPU Temperature~

  • Manufacturer: Raspberry Pi
  • Measurements: Temperature
  • Interfaces: RPi

The internal CPU and GPU temperature of the Raspberry Pi.

OptionTypeDescription
Measurements EnabledMulti-SelectThe measurements to record
Period (Seconds)DecimalThe duration between measurements or actions
Path for CPU TemperatureText - Default Value: /sys/class/thermal/thermal_zone0/tempReads the CPU temperature from this file
Path to vcgencmdText - Default Value: /usr/bin/vcgencmdReads the GPU from vcgencmd

Raspberry Pi: Edge Detection~

  • Manufacturer: Raspberry Pi
  • Measurements: Rising/Falling Edge
  • Interfaces: GPIO
  • Libraries: RPi.GPIO
  • Dependencies: RPi.GPIO
OptionTypeDescription
Pre OutputSelectTurn the selected output on before taking every measurement
Pre Out Duration (Seconds)DecimalIf a Pre Output is selected, set the duration to turn the Pre Output on for before every measurement is acquired.
Pre During MeasureBooleanCheck to turn the output off after (opposed to before) the measurement is complete
Pin ModeSelect(Options: [Floating | Pull Down | Pull Up] (Default in bold)Enables or disables the pull-up or pull-down resistor

Raspberry Pi: GPIO State~

  • Manufacturer: Raspberry Pi
  • Measurements: GPIO State
  • Interfaces: GPIO
  • Libraries: RPi.GPIO
  • Dependencies: RPi.GPIO

Measures the state of a GPIO pin, returning either 0 (low) or 1 (high).

OptionTypeDescription
Period (Seconds)DecimalThe duration between measurements or actions
Pre OutputSelectTurn the selected output on before taking every measurement
Pre Out Duration (Seconds)DecimalIf a Pre Output is selected, set the duration to turn the Pre Output on for before every measurement is acquired.
Pre During MeasureBooleanCheck to turn the output off after (opposed to before) the measurement is complete
Pin ModeSelect(Options: [Floating | Pull Down | Pull Up] (Default in bold)Enables or disables the pull-up or pull-down resistor

Raspberry Pi: Signal (PWM)~

  • Manufacturer: Raspberry Pi
  • Measurements: Frequency/Pulse Width/Duty Cycle
  • Interfaces: GPIO
  • Libraries: pigpio
  • Dependencies: pigpio, pigpio
OptionTypeDescription
Measurements EnabledMulti-SelectThe measurements to record
Period (Seconds)DecimalThe duration between measurements or actions
Pre OutputSelectTurn the selected output on before taking every measurement
Pre Out Duration (Seconds)DecimalIf a Pre Output is selected, set the duration to turn the Pre Output on for before every measurement is acquired.
Pre During MeasureBooleanCheck to turn the output off after (opposed to before) the measurement is complete

Raspberry Pi: Signal (Revolutions) (pigpio method #1)~

  • Manufacturer: Raspberry Pi
  • Measurements: RPM
  • Interfaces: GPIO
  • Libraries: pigpio
  • Dependencies: pigpio, pigpio

This calculates RPM from pulses on a pin using pigpio, but has been found to be less accurate than the method #2 module. This is typically used to measure the speed of a fan from a tachometer pin, however this can be used to measure any 3.3-volt pulses from a wire. Use a resistor to pull the measurement pin to 3.3 volts, set pigpio to the lowest latency (1 ms) on the Configure -> Raspberry Pi page. Note 1: Not setting pigpio to the lowest latency will hinder accuracy. Note 2: accuracy decreases as RPM increases.

OptionTypeDescription
Period (Seconds)DecimalThe duration between measurements or actions
Pre OutputSelectTurn the selected output on before taking every measurement
Pre Out Duration (Seconds)DecimalIf a Pre Output is selected, set the duration to turn the Pre Output on for before every measurement is acquired.
Pre During MeasureBooleanCheck to turn the output off after (opposed to before) the measurement is complete

Raspberry Pi: Signal (Revolutions) (pigpio method #2)~

  • Manufacturer: Raspberry Pi
  • Measurements: RPM
  • Interfaces: GPIO
  • Libraries: pigpio
  • Dependencies: pigpio, pigpio

This is an alternate method to calculate RPM from pulses on a pin using pigpio, and has been found to be more accurate than the method #1 module. This is typically used to measure the speed of a fan from a tachometer pin, however this can be used to measure any 3.3-volt pulses from a wire. Use a resistor to pull the measurement pin to 3.3 volts, set pigpio to the lowest latency (1 ms) on the Configure -> Raspberry Pi page. Note 1: Not setting pigpio to the lowest latency will hinder accuracy. Note 2: accuracy decreases as RPM increases.

OptionTypeDescription
Period (Seconds)DecimalThe duration between measurements or actions
Pre OutputSelectTurn the selected output on before taking every measurement
Pre Out Duration (Seconds)DecimalIf a Pre Output is selected, set the duration to turn the Pre Output on for before every measurement is acquired.
Pre During MeasureBooleanCheck to turn the output off after (opposed to before) the measurement is complete
Pin: GPIO (BCM)IntegerThe pin to measure pulses from
Sample Time (Seconds)Decimal - Default Value: 5.0The duration of time to sample
Pulses Per RevDecimal - Default Value: 15.8The number of pulses per revolution to calculate revolutions per minute (RPM)

Built-In Inputs (Devices)~

AMS: AS7262~

  • Manufacturer: AMS
  • Measurements: Light at 450, 500, 550, 570, 600, 650 nm
  • Interfaces: I2C
  • Libraries: as7262
  • Dependencies: as7262
  • Manufacturer URL: Link
  • Datasheet URL: Link
  • Product URL: Link
OptionTypeDescription
Period (Seconds)DecimalThe duration between measurements or actions
Pre OutputSelectTurn the selected output on before taking every measurement
Pre Out Duration (Seconds)DecimalIf a Pre Output is selected, set the duration to turn the Pre Output on for before every measurement is acquired.
Pre During MeasureBooleanCheck to turn the output off after (opposed to before) the measurement is complete
GainSelect(Options: [1x | 3.7x | 16x | 64x] (Default in bold)Set the sensor gain
Illumination LED CurrentSelect(Options: [12.5 mA | 25 mA | 50 mA | 100 mA] (Default in bold)Set the illumination LED current (milliamps)
Illumination LED ModeSelect(Options: [On | Off] (Default in bold)Turn the illumination LED on or off during a measurement
Indicator LED CurrentSelect(Options: [1 mA | 2 mA | 4 mA | 8 mA] (Default in bold)Set the indicator LED current (milliamps)
Indicator LED ModeSelect(Options: [On | Off] (Default in bold)Turn the indicator LED on or off during a measurement
Integration TimeDecimal - Default Value: 15.0The integration time (0 - ~91 ms)

AMS: CCS811 (with Temperature)~

OptionTypeDescription
I2C AddressTextThe address of the I2C device.
I2C BusIntegerThe Bus the I2C device is connected.
Measurements EnabledMulti-SelectThe measurements to record
Period (Seconds)DecimalThe duration between measurements or actions
Pre OutputSelectTurn the selected output on before taking every measurement
Pre Out Duration (Seconds)DecimalIf a Pre Output is selected, set the duration to turn the Pre Output on for before every measurement is acquired.
Pre During MeasureBooleanCheck to turn the output off after (opposed to before) the measurement is complete

AMS: CCS811 (without Temperature)~

OptionTypeDescription
I2C AddressTextThe address of the I2C device.
I2C BusIntegerThe Bus the I2C device is connected.
Measurements EnabledMulti-SelectThe measurements to record
Period (Seconds)DecimalThe duration between measurements or actions
Pre OutputSelectTurn the selected output on before taking every measurement
Pre Out Duration (Seconds)DecimalIf a Pre Output is selected, set the duration to turn the Pre Output on for before every measurement is acquired.
Pre During MeasureBooleanCheck to turn the output off after (opposed to before) the measurement is complete

AMS: TSL2561~

OptionTypeDescription
I2C AddressTextThe address of the I2C device.
I2C BusIntegerThe Bus the I2C device is connected.
Measurements EnabledMulti-SelectThe measurements to record
Period (Seconds)DecimalThe duration between measurements or actions
Pre OutputSelectTurn the selected output on before taking every measurement
Pre Out Duration (Seconds)DecimalIf a Pre Output is selected, set the duration to turn the Pre Output on for before every measurement is acquired.
Pre During MeasureBooleanCheck to turn the output off after (opposed to before) the measurement is complete

AMS: TSL2591~

  • Manufacturer: AMS
  • Measurements: Light
  • Interfaces: I2C
  • Libraries: maxlklaxl/python-tsl2591
  • Dependencies: tsl2591
  • Manufacturer URL: Link
  • Datasheet URL: Link
  • Product URL: Link
OptionTypeDescription
I2C AddressTextThe address of the I2C device.
I2C BusIntegerThe Bus the I2C device is connected.
Measurements EnabledMulti-SelectThe measurements to record
Period (Seconds)DecimalThe duration between measurements or actions
Pre OutputSelectTurn the selected output on before taking every measurement
Pre Out Duration (Seconds)DecimalIf a Pre Output is selected, set the duration to turn the Pre Output on for before every measurement is acquired.
Pre During MeasureBooleanCheck to turn the output off after (opposed to before) the measurement is complete

AOSONG: AM2315/AM2320~

  • Manufacturer: AOSONG
  • Measurements: Humidity/Temperature
  • Interfaces: I2C
  • Libraries: quick2wire-api
  • Dependencies: quick2wire-api
  • Datasheet URL: Link
  • Product URL: Link
OptionTypeDescription
Measurements EnabledMulti-SelectThe measurements to record
Period (Seconds)DecimalThe duration between measurements or actions
Pre OutputSelectTurn the selected output on before taking every measurement
Pre Out Duration (Seconds)DecimalIf a Pre Output is selected, set the duration to turn the Pre Output on for before every measurement is acquired.
Pre During MeasureBooleanCheck to turn the output off after (opposed to before) the measurement is complete

AOSONG: AM2315C~

  • Manufacturer: AOSONG
  • Measurements: Humidity/Temperature
  • Interfaces: I2C
  • Libraries: quick2wire-api
  • Dependencies: quick2wire-api
  • Datasheet URL: Link
  • Product URL: Link
OptionTypeDescription
I2C AddressTextThe address of the I2C device.
I2C BusIntegerThe Bus the I2C device is connected.
Measurements EnabledMulti-SelectThe measurements to record
Period (Seconds)DecimalThe duration between measurements or actions
Pre OutputSelectTurn the selected output on before taking every measurement
Pre Out Duration (Seconds)DecimalIf a Pre Output is selected, set the duration to turn the Pre Output on for before every measurement is acquired.
Pre During MeasureBooleanCheck to turn the output off after (opposed to before) the measurement is complete

AOSONG: DHT11~

  • Manufacturer: AOSONG
  • Measurements: Humidity/Temperature
  • Interfaces: GPIO
  • Libraries: pigpio
  • Dependencies: pigpio, pigpio
  • Datasheet URL: Link
  • Product URL: Link
OptionTypeDescription
Measurements EnabledMulti-SelectThe measurements to record
Period (Seconds)DecimalThe duration between measurements or actions
Pre OutputSelectTurn the selected output on before taking every measurement
Pre Out Duration (Seconds)DecimalIf a Pre Output is selected, set the duration to turn the Pre Output on for before every measurement is acquired.
Pre During MeasureBooleanCheck to turn the output off after (opposed to before) the measurement is complete

AOSONG: DHT20~

  • Manufacturer: AOSONG
  • Measurements: Humidity/Temperature
  • Interfaces: I2C
  • Libraries: smbus2
  • Dependencies: smbus2
  • Manufacturer URL: Link
  • Datasheet URL: Link
  • Product URLs: Link 1, Link 2, Link 3
OptionTypeDescription
Measurements EnabledMulti-SelectThe measurements to record
Period (Seconds)DecimalThe duration between measurements or actions
Pre OutputSelectTurn the selected output on before taking every measurement
Pre Out Duration (Seconds)DecimalIf a Pre Output is selected, set the duration to turn the Pre Output on for before every measurement is acquired.
Pre During MeasureBooleanCheck to turn the output off after (opposed to before) the measurement is complete

AOSONG: DHT22~

  • Manufacturer: AOSONG
  • Measurements: Humidity/Temperature
  • Interfaces: GPIO
  • Libraries: pigpio
  • Dependencies: pigpio, pigpio
  • Datasheet URL: Link
  • Product URL: Link
OptionTypeDescription
Measurements EnabledMulti-SelectThe measurements to record
Period (Seconds)DecimalThe duration between measurements or actions
Pre OutputSelectTurn the selected output on before taking every measurement
Pre Out Duration (Seconds)DecimalIf a Pre Output is selected, set the duration to turn the Pre Output on for before every measurement is acquired.
Pre During MeasureBooleanCheck to turn the output off after (opposed to before) the measurement is complete

ASAIR: AHTx0~

OptionTypeDescription
I2C AddressTextThe address of the I2C device.
I2C BusIntegerThe Bus the I2C device is connected.
Period (Seconds)DecimalThe duration between measurements or actions
Pre OutputSelectTurn the selected output on before taking every measurement
Pre Out Duration (Seconds)DecimalIf a Pre Output is selected, set the duration to turn the Pre Output on for before every measurement is acquired.
Pre During MeasureBooleanCheck to turn the output off after (opposed to before) the measurement is complete

Adafruit: I2C Capacitive Moisture Sensor~

OptionTypeDescription
I2C AddressTextThe address of the I2C device.
I2C BusIntegerThe Bus the I2C device is connected.
Measurements EnabledMulti-SelectThe measurements to record
Period (Seconds)DecimalThe duration between measurements or actions
Pre OutputSelectTurn the selected output on before taking every measurement
Pre Out Duration (Seconds)DecimalIf a Pre Output is selected, set the duration to turn the Pre Output on for before every measurement is acquired.
Pre During MeasureBooleanCheck to turn the output off after (opposed to before) the measurement is complete

Analog Devices: ADT7410~

OptionTypeDescription
I2C AddressTextThe address of the I2C device.
I2C BusIntegerThe Bus the I2C device is connected.
Measurements EnabledMulti-SelectThe measurements to record
Period (Seconds)DecimalThe duration between measurements or actions
Pre OutputSelectTurn the selected output on before taking every measurement
Pre Out Duration (Seconds)DecimalIf a Pre Output is selected, set the duration to turn the Pre Output on for before every measurement is acquired.
Pre During MeasureBooleanCheck to turn the output off after (opposed to before) the measurement is complete

Analog Devices: ADXL34x (343, 344, 345, 346)~

OptionTypeDescription
I2C AddressTextThe address of the I2C device.
I2C BusIntegerThe Bus the I2C device is connected.
Measurements EnabledMulti-SelectThe measurements to record
Period (Seconds)DecimalThe duration between measurements or actions
Pre OutputSelectTurn the selected output on before taking every measurement
Pre Out Duration (Seconds)DecimalIf a Pre Output is selected, set the duration to turn the Pre Output on for before every measurement is acquired.
Pre During MeasureBooleanCheck to turn the output off after (opposed to before) the measurement is complete
RangeSelect(Options: [±2 g (±19.6 m/s/s) | ±4 g (±39.2 m/s/s) | ±8 g (±78.4 m/s/s) | ±16 g (±156.9 m/s/s)] (Default in bold)Set the measurement range

AnyLeaf: AnyLeaf EC~

OptionTypeDescription
UART DeviceTextThe UART device location (e.g. /dev/ttyUSB1)
Period (Seconds)DecimalThe duration between measurements or actions
Conductivity ConstantDecimal - Default Value: 1.0Conductivity constant K

AnyLeaf: AnyLeaf ORP~

OptionTypeDescription
I2C AddressTextThe address of the I2C device.
I2C BusIntegerThe Bus the I2C device is connected.
Period (Seconds)DecimalThe duration between measurements or actions
Calibrate: Voltage (Internal)Decimal - Default Value: 0.4Calibration data: internal voltage
Calibrate: ORP (Internal)Decimal - Default Value: 400.0Calibration data: internal ORP
Commands
Calibrate: Buffer ORP (mV)Decimal - Default Value: 400.0This is the nominal ORP of the calibration buffer in mV, usually labelled on the bottle.
CalibrateButton
Clear Calibration SlotsButton

AnyLeaf: AnyLeaf pH~

OptionTypeDescription
I2C AddressTextThe address of the I2C device.
I2C BusIntegerThe Bus the I2C device is connected.
Period (Seconds)DecimalThe duration between measurements or actions
Temperature Compensation: MeasurementSelect Measurement (Input, Function)Select a measurement for temperature compensation
Temperature Compensation: Max Age (Seconds)Integer - Default Value: 120The maximum age of the measurement to use
Cal data: V1 (internal)DecimalCalibration data: Voltage
Cal data: pH1 (internal)Decimal - Default Value: 7.0Calibration data: pH
Cal data: T1 (internal)Decimal - Default Value: 23.0Calibration data: Temperature
Cal data: V2 (internal)Decimal - Default Value: 0.17Calibration data: Voltage
Cal data: pH2 (internal)Decimal - Default Value: 4.0Calibration data: pH
Cal data: T2 (internal)Decimal - Default Value: 23.0Calibration data: Temperature
Cal data: V3 (internal)DecimalCalibration data: Voltage
Cal data: pH3 (internal)DecimalCalibration data: pH
Cal data: T3 (internal)DecimalCalibration data: Temperature
Commands
Calibration buffer pHDecimal - Default Value: 7.0This is the nominal pH of the calibration buffer, usually labelled on the bottle.
Calibrate, slot 1Button
Calibrate, slot 2Button
Calibrate, slot 3Button
Clear Calibration SlotsButton

Atlas Scientific: Atlas CO2 (Carbon Dioxide Gas)~

  • Manufacturer: Atlas Scientific
  • Measurements: CO2
  • Interfaces: I2C, UART, FTDI
  • Libraries: pylibftdi/fcntl/io/serial
  • Dependencies: pylibftdi
  • Manufacturer URL: Link
  • Datasheet URL: Link
OptionTypeDescription
I2C AddressTextThe address of the I2C device.
I2C BusIntegerThe Bus the I2C device is connected.
FTDI DeviceTextThe FTDI device connected to the input/output/etc.
UART DeviceTextThe UART device location (e.g. /dev/ttyUSB1)
Period (Seconds)DecimalThe duration between measurements or actions
Pre OutputSelectTurn the selected output on before taking every measurement
Pre Out Duration (Seconds)DecimalIf a Pre Output is selected, set the duration to turn the Pre Output on for before every measurement is acquired.
Pre During MeasureBooleanCheck to turn the output off after (opposed to before) the measurement is complete
Commands
A one- or two-point calibration can be performed. After exposing the probe to a concentration of CO2 between 3,000 and 5,000 ppmv until readings stabilize, press Calibrate (High). You can place the probe in a 0 CO2 environment until readings stabilize, then press Calibrate (Zero). You can also clear the currently-saved calibration by pressing Clear Calibration, returning to the factory-set calibration. Status messages will be sent to the Daemon Log, accessible from Config -> AoT Logs -> Daemon Log.
High Point CO2Integer - Default Value: 3000The high CO2 calibration point (3000 - 5000 ppmv)
Calibrate (High)Button
Calibrate (Zero)Button
Clear CalibrationButton
The I2C address can be changed. Enter a new address in the 0xYY format (e.g. 0x22, 0x50), then press Set I2C Address. Remember to deactivate and change the I2C address option after setting the new address.
New I2C AddressText - Default Value: 0x69The new I2C to set the device to
Set I2C AddressButton

Atlas Scientific: Atlas Color~

  • Manufacturer: Atlas Scientific
  • Measurements: RGB, CIE, LUX, Proximity
  • Interfaces: I2C, UART, FTDI
  • Libraries: pylibftdi/fcntl/io/serial
  • Dependencies: pylibftdi
  • Manufacturer URL: Link
  • Datasheet URL: Link
OptionTypeDescription
I2C AddressTextThe address of the I2C device.
I2C BusIntegerThe Bus the I2C device is connected.
FTDI DeviceTextThe FTDI device connected to the input/output/etc.
UART DeviceTextThe UART device location (e.g. /dev/ttyUSB1)
Measurements EnabledMulti-SelectThe measurements to record
Period (Seconds)DecimalThe duration between measurements or actions
Pre OutputSelectTurn the selected output on before taking every measurement
Pre Out Duration (Seconds)DecimalIf a Pre Output is selected, set the duration to turn the Pre Output on for before every measurement is acquired.
Pre During MeasureBooleanCheck to turn the output off after (opposed to before) the measurement is complete
LED Only For MeasureBoolean - Default Value: TrueTurn the LED on only during the measurement
LED PercentageInteger - Default Value: 30What percentage of power to supply to the LEDs during measurement
Gamma CorrectionDecimal - Default Value: 1.0Gamma correction between 0.01 and 4.99 (default is 1.0)
Commands
The EZO-RGB color sensor is designed to be calibrated to a white object at the maximum brightness the object will be viewed under. In order to get the best results, Atlas Scientific strongly recommends that the sensor is mounted into a fixed location. Holding the sensor in your hand during calibration will decrease performance.
1. Embed the EZO-RGB color sensor into its intended use location.
2. Set LED brightness to the desired level.
3. Place a white object in front of the target object and press the Calibration button.
4. A single color reading will be taken and the device will be fully calibrated.
CalibrateButton
The I2C address can be changed. Enter a new address in the 0xYY format (e.g. 0x22, 0x50), then press Set I2C Address. Remember to deactivate and change the I2C address option after setting the new address.
New I2C AddressText - Default Value: 0x70The new I2C to set the device to
Set I2C AddressButton

Atlas Scientific: Atlas DO~

  • Manufacturer: Atlas Scientific
  • Measurements: Dissolved Oxygen
  • Interfaces: I2C, UART, FTDI
  • Libraries: pylibftdi/fcntl/io/serial
  • Dependencies: pylibftdi
  • Manufacturer URL: Link
  • Datasheet URL: Link
OptionTypeDescription
I2C AddressTextThe address of the I2C device.
I2C BusIntegerThe Bus the I2C device is connected.
FTDI DeviceTextThe FTDI device connected to the input/output/etc.
UART DeviceTextThe UART device location (e.g. /dev/ttyUSB1)
Period (Seconds)DecimalThe duration between measurements or actions
Pre OutputSelectTurn the selected output on before taking every measurement
Pre Out Duration (Seconds)DecimalIf a Pre Output is selected, set the duration to turn the Pre Output on for before every measurement is acquired.
Pre During MeasureBooleanCheck to turn the output off after (opposed to before) the measurement is complete
Temperature Compensation: MeasurementSelect Measurement (Input, Function)Select a measurement for temperature compensation
Temperature Compensation: Max Age (Seconds)Integer - Default Value: 120The maximum age of the measurement to use
Commands
A one- or two-point calibration can be performed. After exposing the probe to air for 30 seconds until readings stabilize, press Calibrate (Air). If you require accuracy below 1.0 mg/L, you can place the probe in a 0 mg/L solution for 30 to 90 seconds until readings stabilize, then press Calibrate (0 mg/L). You can also clear the currently-saved calibration by pressing Clear Calibration. Status messages will be sent to the Daemon Log, accessible from Config -> AoT Logs -> Daemon Log.
Calibrate (Air)Button
Calibrate (0 mg/L)Button
Clear CalibrationButton
The I2C address can be changed. Enter a new address in the 0xYY format (e.g. 0x22, 0x50), then press Set I2C Address. Remember to deactivate and change the I2C address option after setting the new address.
New I2C AddressText - Default Value: 0x66The new I2C to set the device to
Set I2C AddressButton

Atlas Scientific: Atlas EC~

  • Manufacturer: Atlas Scientific
  • Measurements: Electrical Conductivity
  • Interfaces: I2C, UART, FTDI
  • Libraries: pylibftdi/fcntl/io/serial
  • Dependencies: pylibftdi
  • Manufacturer URL: Link
  • Datasheet URL: Link
OptionTypeDescription
I2C AddressTextThe address of the I2C device.
I2C BusIntegerThe Bus the I2C device is connected.
FTDI DeviceTextThe FTDI device connected to the input/output/etc.
UART DeviceTextThe UART device location (e.g. /dev/ttyUSB1)
Measurements EnabledMulti-SelectThe measurements to record
Period (Seconds)DecimalThe duration between measurements or actions
Pre OutputSelectTurn the selected output on before taking every measurement
Pre Out Duration (Seconds)DecimalIf a Pre Output is selected, set the duration to turn the Pre Output on for before every measurement is acquired.
Pre During MeasureBooleanCheck to turn the output off after (opposed to before) the measurement is complete
Temperature Compensation: MeasurementSelect Measurement (Input, Function)Select a measurement for temperature compensation
Temperature Compensation: Max Age (Seconds)Integer - Default Value: 120The maximum age of the measurement to use
Commands
Calibration: a one- or two-point calibration can be performed. It's a good idea to clear the calibration before calibrating. Always perform a dry calibration with the probe in the air (not in any fluid). Then perform either a one- or two-point calibration with calibrated solutions. If performing a one-point calibration, use the Single Point Calibration field and button. If performing a two-point calibration, use the Low and High Point Calibration fields and buttons. Allow a minute or two after submerging your probe in a calibration solution for the measurements to equilibrate before calibrating to that solution. The EZO EC circuit default temperature compensation is set to 25 °C. If the temperature of the calibration solution is +/- 2 °C from 25 °C, consider setting the temperature compensation first. Note that at no point should you change the temperature compensation value during calibration. Therefore, if you have previously enabled temperature compensation, allow at least one measurement to occur (to set the compensation value), then disable the temperature compensation measurement while you calibrate. Status messages will be sent to the Daemon Log, accessible from Config -> AoT Logs -> Daemon Log.
Clear CalibrationButton
Calibrate DryButton
Single Point EC (µS)Integer - Default Value: 84The EC (µS) of the single point calibration solution
Calibrate Single PointButton
Low Point EC (µS)Integer - Default Value: 12880The EC (µS) of the low point calibration solution
Calibrate Low PointButton
High Point EC (µS)Integer - Default Value: 80000The EC (µS) of the high point calibration solution
Calibrate High PointButton
The I2C address can be changed. Enter a new address in the 0xYY format (e.g. 0x22, 0x50), then press Set I2C Address. Remember to deactivate and change the I2C address option after setting the new address.
New I2C AddressText - Default Value: 0x64The new I2C to set the device to
Set I2C AddressButton

Atlas Scientific: Atlas Flow Meter~

  • Manufacturer: Atlas Scientific
  • Measurements: Total Volume, Flow Rate
  • Interfaces: I2C, UART, FTDI
  • Libraries: pylibftdi/fcntl/io/serial
  • Dependencies: pylibftdi
  • Manufacturer URL: Link
  • Datasheet URL: Link

Set the Measurement Time Base to a value most appropriate for your anticipated flow (it will affect accuracy). This flow rate time base that is set and returned from the sensor will be converted to liters per minute, which is the default unit for this input module. If you desire a different rate to be stored in the database (such as liters per second or hour), then use the Convert to Unit option.

OptionTypeDescription
I2C AddressTextThe address of the I2C device.
I2C BusIntegerThe Bus the I2C device is connected.
FTDI DeviceTextThe FTDI device connected to the input/output/etc.
UART DeviceTextThe UART device location (e.g. /dev/ttyUSB1)
Measurements EnabledMulti-SelectThe measurements to record
Period (Seconds)DecimalThe duration between measurements or actions
Pre OutputSelectTurn the selected output on before taking every measurement
Pre Out Duration (Seconds)DecimalIf a Pre Output is selected, set the duration to turn the Pre Output on for before every measurement is acquired.
Pre During MeasureBooleanCheck to turn the output off after (opposed to before) the measurement is complete
Flow Meter TypeSelect(Options: [Atlas Scientific 3/8" Flow Meter | Atlas Scientific 1/4" Flow Meter | Atlas Scientific 1/2" Flow Meter | Atlas Scientific 3/4" Flow Meter | Non-Atlas Scientific Flow Meter] (Default in bold)Set the type of flow meter used
Atlas Meter Time BaseSelect(Options: [Liters per Second | Liters per Minute | Liters per Hour] (Default in bold)If using an Atlas Scientific flow meter, set the flow rate/time base
Internal ResistorSelect(Options: [Use Atlas Scientific Flow Meter | Disable Internal Resistor | 1 K Ω Pull-Up | 1 K Ω Pull-Down | 10 K Ω Pull-Up | 10 K Ω Pull-Down | 100 K Ω Pull-Up | 100 K Ω Pull-Down] (Default in bold)Set an internal resistor for the flow meter
Custom K Value(s)TextIf using a non-Atlas Scientific flow meter, enter the meter's K value(s). For a single K value, enter '[volume per pulse],[number of pulses]'. For multiple K values (up to 16), enter '[volume at frequency],[frequency in Hz];[volume at frequency],[frequency in Hz];...'. Leave blank to disable.
K Value Time BaseSelect(Options: [Use Atlas Scientific Flow Meter | Liters per Second | Liters per Minute | Liters per Hour] (Default in bold)If using a non-Atlas Scientific flow meter, set the flow rate/time base for the custom K values entered.
Commands
The total volume can be cleared with the following button or with the Clear Total Volume Function Action.
Clear Total: VolumeButton
The I2C address can be changed. Enter a new address in the 0xYY format (e.g. 0x22, 0x50), then press Set I2C Address. Remember to deactivate and change the I2C address option after setting the new address.
New I2C AddressText - Default Value: 0x68The new I2C to set the device to
Set I2C AddressButton

Atlas Scientific: Atlas Humidity~

  • Manufacturer: Atlas Scientific
  • Measurements: Humidity/Temperature
  • Interfaces: I2C, UART, FTDI
  • Libraries: pylibftdi/fcntl/io/serial
  • Dependencies: pylibftdi
  • Manufacturer URL: Link
  • Datasheet URL: Link
OptionTypeDescription
I2C AddressTextThe address of the I2C device.
I2C BusIntegerThe Bus the I2C device is connected.
FTDI DeviceTextThe FTDI device connected to the input/output/etc.
UART DeviceTextThe UART device location (e.g. /dev/ttyUSB1)
Measurements EnabledMulti-SelectThe measurements to record
Period (Seconds)DecimalThe duration between measurements or actions
Pre OutputSelectTurn the selected output on before taking every measurement
Pre Out Duration (Seconds)DecimalIf a Pre Output is selected, set the duration to turn the Pre Output on for before every measurement is acquired.
Pre During MeasureBooleanCheck to turn the output off after (opposed to before) the measurement is complete
LED ModeSelect(Options: [Always On | Always Off | Only On During Measure] (Default in bold)When to turn the LED on
Commands
New I2C AddressText - Default Value: 0x6fThe new I2C to set the device to
Set I2C AddressButton

Atlas Scientific: Atlas O2 (Oxygen Gas)~

  • Manufacturer: Atlas Scientific
  • Measurements: O2
  • Interfaces: I2C, UART, FTDI
  • Libraries: pylibftdi/fcntl/io/serial
  • Dependencies: pylibftdi
  • Manufacturer URL: Link
  • Datasheet URL: Link
OptionTypeDescription
I2C AddressTextThe address of the I2C device.
I2C BusIntegerThe Bus the I2C device is connected.
FTDI DeviceTextThe FTDI device connected to the input/output/etc.
UART DeviceTextThe UART device location (e.g. /dev/ttyUSB1)
Period (Seconds)DecimalThe duration between measurements or actions
Pre OutputSelectTurn the selected output on before taking every measurement
Pre Out Duration (Seconds)DecimalIf a Pre Output is selected, set the duration to turn the Pre Output on for before every measurement is acquired.
Pre During MeasureBooleanCheck to turn the output off after (opposed to before) the measurement is complete
Temperature Compensation: MeasurementSelect Measurement (Input, Function)Select a measurement for temperature compensation
Temperature Compensation: Max Age (Seconds)Integer - Default Value: 120The maximum age of the measurement to use
Temperature Compensation: ManualDecimal - Default Value: 20.0If not using a measurement, set the temperature to compensate
LED ModeSelect(Options: [Always On | Always Off | Only On During Measure] (Default in bold)When to turn the LED on
Commands
A one- or two-point calibration can be performed. After exposing the probe to a specific concentration of O2 until readings stabilize, press Calibrate (High). You can place the probe in a 0% O2 environment until readings stabilize, then press Calibrate (Zero). You can also clear the currently-saved calibration by pressing Clear Calibration, returning to the factory-set calibration. Status messages will be sent to the Daemon Log, accessible from Config -> AoT Logs -> Daemon Log.
High Point O2Decimal - Default Value: 20.95The high O2 calibration point (percent)
Calibrate (High)Button
Calibrate (Zero)Button
Clear CalibrationButton
The I2C address can be changed. Enter a new address in the 0xYY format (e.g. 0x22, 0x50), then press Set I2C Address. Remember to deactivate and change the I2C address option after setting the new address.
New I2C AddressText - Default Value: 0x69The new I2C to set the device to
Set I2C AddressButton

Atlas Scientific: Atlas ORP~

  • Manufacturer: Atlas Scientific
  • Measurements: Oxidation Reduction Potential
  • Interfaces: I2C, UART, FTDI
  • Libraries: pylibftdi/fcntl/io/serial
  • Dependencies: pylibftdi
  • Manufacturer URL: Link
  • Datasheet URL: Link
OptionTypeDescription
I2C AddressTextThe address of the I2C device.
I2C BusIntegerThe Bus the I2C device is connected.
FTDI DeviceTextThe FTDI device connected to the input/output/etc.
UART DeviceTextThe UART device location (e.g. /dev/ttyUSB1)
Period (Seconds)DecimalThe duration between measurements or actions
Pre OutputSelectTurn the selected output on before taking every measurement
Pre Out Duration (Seconds)DecimalIf a Pre Output is selected, set the duration to turn the Pre Output on for before every measurement is acquired.
Pre During MeasureBooleanCheck to turn the output off after (opposed to before) the measurement is complete
Temperature Compensation: MeasurementSelect Measurement (Input, Function)Select a measurement for temperature compensation
Temperature Compensation: Max Age (Seconds)Integer - Default Value: 120The maximum age of the measurement to use
Commands
A one-point calibration can be performed. Enter the solution's mV, set the probe in the solution, then press Calibrate. You can also clear the currently-saved calibration by pressing Clear Calibration. Status messages will be sent to the Daemon Log, accessible from Config -> AoT Logs -> Daemon Log.
Calibration Solution mVInteger - Default Value: 225The value of the calibration solution, in mV
CalibrateButton
Clear CalibrationButton
The I2C address can be changed. Enter a new address in the 0xYY format (e.g. 0x22, 0x50), then press Set I2C Address. Remember to deactivate and change the I2C address option after setting the new address.
New I2C AddressText - Default Value: 0x62The new I2C to set the device to
Set I2C AddressButton

Atlas Scientific: Atlas PT-1000~

  • Manufacturer: Atlas Scientific
  • Measurements: Temperature
  • Interfaces: I2C, UART, FTDI
  • Libraries: pylibftdi/fcntl/io/serial
  • Dependencies: pylibftdi
  • Manufacturer URL: Link
  • Datasheet URL: Link
OptionTypeDescription
I2C AddressTextThe address of the I2C device.
I2C BusIntegerThe Bus the I2C device is connected.
FTDI DeviceTextThe FTDI device connected to the input/output/etc.
UART DeviceTextThe UART device location (e.g. /dev/ttyUSB1)
Period (Seconds)DecimalThe duration between measurements or actions
Pre OutputSelectTurn the selected output on before taking every measurement
Pre Out Duration (Seconds)DecimalIf a Pre Output is selected, set the duration to turn the Pre Output on for before every measurement is acquired.
Pre During MeasureBooleanCheck to turn the output off after (opposed to before) the measurement is complete
Commands
New I2C AddressText - Default Value: 0x66The new I2C to set the device to
Set I2C AddressButton
Temperature (°C)Decimal - Default Value: 100.0Temperature for single point calibration
CalibrateButton
Clear CalibrationButton

Atlas Scientific: Atlas Pressure~

  • Manufacturer: Atlas Scientific
  • Measurements: Pressure
  • Interfaces: I2C, UART, FTDI
  • Libraries: pylibftdi/fcntl/io/serial
  • Dependencies: pylibftdi
  • Manufacturer URL: Link
  • Datasheet URL: Link
OptionTypeDescription
I2C AddressTextThe address of the I2C device.
I2C BusIntegerThe Bus the I2C device is connected.
FTDI DeviceTextThe FTDI device connected to the input/output/etc.
UART DeviceTextThe UART device location (e.g. /dev/ttyUSB1)
Period (Seconds)DecimalThe duration between measurements or actions
Pre OutputSelectTurn the selected output on before taking every measurement
Pre Out Duration (Seconds)DecimalIf a Pre Output is selected, set the duration to turn the Pre Output on for before every measurement is acquired.
Pre During MeasureBooleanCheck to turn the output off after (opposed to before) the measurement is complete
LED ModeSelect(Options: [Always On | Always Off | Only On During Measure] (Default in bold)When to turn the LED on
Commands
New I2C AddressText - Default Value: 0x6aThe new I2C to set the device to
Set I2C AddressButton

Atlas Scientific: Atlas pH~

  • Manufacturer: Atlas Scientific
  • Measurements: Ion Concentration
  • Interfaces: I2C, UART, FTDI
  • Libraries: pylibftdi/fcntl/io/serial
  • Dependencies: pylibftdi
  • Manufacturer URL: Link
  • Datasheet URL: Link

Calibration Measurement is an optional setting that provides a temperature measurement (in Celsius) of the water that the pH is being measured from.

OptionTypeDescription
I2C AddressTextThe address of the I2C device.
I2C BusIntegerThe Bus the I2C device is connected.
FTDI DeviceTextThe FTDI device connected to the input/output/etc.
UART DeviceTextThe UART device location (e.g. /dev/ttyUSB1)
Period (Seconds)DecimalThe duration between measurements or actions
Pre OutputSelectTurn the selected output on before taking every measurement
Pre Out Duration (Seconds)DecimalIf a Pre Output is selected, set the duration to turn the Pre Output on for before every measurement is acquired.
Pre During MeasureBooleanCheck to turn the output off after (opposed to before) the measurement is complete
Temperature Compensation: MeasurementSelect Measurement (Input, Function)Select a measurement for temperature compensation
Temperature Compensation: Max Age (Seconds)Integer - Default Value: 120The maximum age of the measurement to use
Commands
Calibration: a one-, two- or three-point calibration can be performed. It's a good idea to clear the calibration before calibrating. The first calibration must be the Mid point. The second must be the Low point. And the third must be the High point. You can perform a one-, two- or three-point calibration, but they must be performed in this order. Allow a minute or two after submerging your probe in a calibration solution for the measurements to equilibrate before calibrating to that solution. The EZO pH circuit default temperature compensation is set to 25 °C. If the temperature of the calibration solution is +/- 2 °C from 25 °C, consider setting the temperature compensation first. Note that if you have a Temperature Compensation Measurement selected from the Options, this will overwrite the manual Temperature Compensation set here, so be sure to disable this option if you would like to specify the temperature to compensate with. Status messages will be sent to the Daemon Log, accessible from Config -> AoT Logs -> Daemon Log.
Compensation Temperature (°C)Decimal - Default Value: 25.0The temperature of the calibration solutions
Set Temperature CompensationButton
Clear CalibrationButton
Mid Point pHDecimal - Default Value: 7.0The pH of the mid point calibration solution
Calibrate MidButton
Low Point pHDecimal - Default Value: 4.0The pH of the low point calibration solution
Calibrate LowButton
High Point pHDecimal - Default Value: 10.0The pH of the high point calibration solution
Calibrate HighButton
Calibration Export/Import: Export calibration to a series of strings. These can later be imported to restore the calibration. Watch the Daemon Log for the output.
Export CalibrationButton
Calibration StringTextThe calibration string to import
Import CalibrationButton
The I2C address can be changed. Enter a new address in the 0xYY format (e.g. 0x22, 0x50), then press Set I2C Address. Remember to deactivate and change the I2C address option after setting the new address.
New I2C AddressText - Default Value: 0x63The new I2C to set the device to
Set I2C AddressButton

BOSCH: BME280 (Adafruit_BME280)~

OptionTypeDescription
I2C AddressTextThe address of the I2C device.
I2C BusIntegerThe Bus the I2C device is connected.
Measurements EnabledMulti-SelectThe measurements to record
Period (Seconds)DecimalThe duration between measurements or actions
Pre OutputSelectTurn the selected output on before taking every measurement
Pre Out Duration (Seconds)DecimalIf a Pre Output is selected, set the duration to turn the Pre Output on for before every measurement is acquired.
Pre During MeasureBooleanCheck to turn the output off after (opposed to before) the measurement is complete

BOSCH: BME280 (Adafruit_CircuitPython_BME280)~

OptionTypeDescription
I2C AddressTextThe address of the I2C device.
I2C BusIntegerThe Bus the I2C device is connected.
Measurements EnabledMulti-SelectThe measurements to record
Period (Seconds)DecimalThe duration between measurements or actions
Pre OutputSelectTurn the selected output on before taking every measurement
Pre Out Duration (Seconds)DecimalIf a Pre Output is selected, set the duration to turn the Pre Output on for before every measurement is acquired.
Pre During MeasureBooleanCheck to turn the output off after (opposed to before) the measurement is complete

BOSCH: BME280 (RPi.bme280)~

  • Manufacturer: BOSCH
  • Measurements: Pressure/Humidity/Temperature
  • Interfaces: I2C
  • Libraries: RPi.bme280
  • Dependencies: RPi.bme280
  • Manufacturer URL: Link
  • Datasheet URL: Link
  • Product URLs: Link 1, Link 2
OptionTypeDescription
I2C AddressTextThe address of the I2C device.
I2C BusIntegerThe Bus the I2C device is connected.
Measurements EnabledMulti-SelectThe measurements to record
Period (Seconds)DecimalThe duration between measurements or actions
Pre OutputSelectTurn the selected output on before taking every measurement
Pre Out Duration (Seconds)DecimalIf a Pre Output is selected, set the duration to turn the Pre Output on for before every measurement is acquired.
Pre During MeasureBooleanCheck to turn the output off after (opposed to before) the measurement is complete

BOSCH: BME680 (Adafruit_CircuitPython_BME680)~

OptionTypeDescription
I2C AddressTextThe address of the I2C device.
I2C BusIntegerThe Bus the I2C device is connected.
Measurements EnabledMulti-SelectThe measurements to record
Period (Seconds)DecimalThe duration between measurements or actions
Pre OutputSelectTurn the selected output on before taking every measurement
Pre Out Duration (Seconds)DecimalIf a Pre Output is selected, set the duration to turn the Pre Output on for before every measurement is acquired.
Pre During MeasureBooleanCheck to turn the output off after (opposed to before) the measurement is complete
Humidity OversamplingSelect(Options: [NONE | 1X | 2X | 4X | 8X | 16X] (Default in bold)A higher oversampling value means more stable readings with less noise and jitter. However each step of oversampling adds ~2 ms latency, causing a slower response time to fast transients.
Temperature OversamplingSelect(Options: [NONE | 1X | 2X | 4X | 8X | 16X] (Default in bold)A higher oversampling value means more stable readings with less noise and jitter. However each step of oversampling adds ~2 ms latency, causing a slower response time to fast transients.
Pressure OversamplingSelect(Options: [NONE | 1X | 2X | 4X | 8X | 16X] (Default in bold)A higher oversampling value means more stable readings with less noise and jitter. However each step of oversampling adds ~2 ms latency, causing a slower response time to fast transients.
IIR Filter SizeSelect(Options: [0 | 1 | 3 | 7 | 15 | 31 | 63 | 127] (Default in bold)Optionally remove short term fluctuations from the temperature and pressure readings, increasing their resolution but reducing their bandwidth.
Temperature OffsetDecimalThe amount to offset the temperature, either negative or positive
Sea Level Pressure (ha)Decimal - Default Value: 1013.25The pressure at sea level for the sensor location

BOSCH: BME680 (bme680)~

  • Manufacturer: BOSCH
  • Measurements: Temperature/Humidity/Pressure/Gas
  • Interfaces: I2C
  • Libraries: bme680
  • Dependencies: bme680, smbus2
  • Manufacturer URL: Link
  • Datasheet URL: Link
  • Product URLs: Link 1, Link 2
OptionTypeDescription
I2C AddressTextThe address of the I2C device.
I2C BusIntegerThe Bus the I2C device is connected.
Measurements EnabledMulti-SelectThe measurements to record
Period (Seconds)DecimalThe duration between measurements or actions
Pre OutputSelectTurn the selected output on before taking every measurement
Pre Out Duration (Seconds)DecimalIf a Pre Output is selected, set the duration to turn the Pre Output on for before every measurement is acquired.
Pre During MeasureBooleanCheck to turn the output off after (opposed to before) the measurement is complete
Humidity OversamplingSelect(Options: [NONE | 1X | 2X | 4X | 8X | 16X] (Default in bold)A higher oversampling value means more stable readings with less noise and jitter. However each step of oversampling adds ~2 ms latency, causing a slower response time to fast transients.
Temperature OversamplingSelect(Options: [NONE | 1X | 2X | 4X | 8X | 16X] (Default in bold)A higher oversampling value means more stable readings with less noise and jitter. However each step of oversampling adds ~2 ms latency, causing a slower response time to fast transients.
Pressure OversamplingSelect(Options: [NONE | 1X | 2X | 4X | 8X | 16X] (Default in bold)A higher oversampling value means more stable readings with less noise and jitter. However each step of oversampling adds ~2 ms latency, causing a slower response time to fast transients.
IIR Filter SizeSelect(Options: [0 | 1 | 3 | 7 | 15 | 31 | 63 | 127] (Default in bold)Optionally remove short term fluctuations from the temperature and pressure readings, increasing their resolution but reducing their bandwidth.
Gas Heater Temperature (°C)Integer - Default Value: 320What temperature to set
Gas Heater Duration (ms)Integer - Default Value: 150How long of a duration to heat. 20-30 ms are necessary for the heater to reach the intended target temperature.
Gas Heater ProfileSelectSelect one of the 10 configured heating durations/set points
Temperature OffsetDecimalThe amount to offset the temperature, either negative or positive

BOSCH: BMP180~

  • Manufacturer: BOSCH
  • Measurements: Pressure/Temperature
  • Interfaces: I2C
  • Libraries: Adafruit_BMP
  • Dependencies: Adafruit-BMP, Adafruit-GPIO
  • Datasheet URL: Link
OptionTypeDescription
Measurements EnabledMulti-SelectThe measurements to record
Period (Seconds)DecimalThe duration between measurements or actions
Pre OutputSelectTurn the selected output on before taking every measurement
Pre Out Duration (Seconds)DecimalIf a Pre Output is selected, set the duration to turn the Pre Output on for before every measurement is acquired.
Pre During MeasureBooleanCheck to turn the output off after (opposed to before) the measurement is complete

BOSCH: BMP280 (Adafruit_GPIO)~

  • Manufacturer: BOSCH
  • Measurements: Pressure/Temperature
  • Interfaces: I2C
  • Libraries: Adafruit_GPIO
  • Dependencies: Adafruit-GPIO
  • Manufacturer URL: Link
  • Datasheet URL: Link
  • Product URL: Link
OptionTypeDescription
I2C AddressTextThe address of the I2C device.
I2C BusIntegerThe Bus the I2C device is connected.
Measurements EnabledMulti-SelectThe measurements to record
Period (Seconds)DecimalThe duration between measurements or actions
Pre OutputSelectTurn the selected output on before taking every measurement
Pre Out Duration (Seconds)DecimalIf a Pre Output is selected, set the duration to turn the Pre Output on for before every measurement is acquired.
Pre During MeasureBooleanCheck to turn the output off after (opposed to before) the measurement is complete

BOSCH: BMP280 (bmp280-python)~

  • Manufacturer: BOSCH
  • Measurements: Pressure/Temperature
  • Interfaces: I2C
  • Libraries: bmp280-python
  • Dependencies: smbus2, bmp280
  • Manufacturer URL: Link
  • Datasheet URL: Link
  • Product URL: Link

This is similar to the other BMP280 Input, except it uses a different library, whcih includes the ability to set forced mode.

OptionTypeDescription
I2C AddressTextThe address of the I2C device.
I2C BusIntegerThe Bus the I2C device is connected.
Measurements EnabledMulti-SelectThe measurements to record
Period (Seconds)DecimalThe duration between measurements or actions
Pre OutputSelectTurn the selected output on before taking every measurement
Pre Out Duration (Seconds)DecimalIf a Pre Output is selected, set the duration to turn the Pre Output on for before every measurement is acquired.
Pre During MeasureBooleanCheck to turn the output off after (opposed to before) the measurement is complete
Enable Forced ModeBooleanEnable heater to evaporate condensation. Turn on heater x seconds every y measurements.

CARTO: GL: Carto Maps~

  • Manufacturer: CARTO
  • Measurements: Status
  • Libraries: gis_carto
  • Manufacturer URL: Link

CARTO DB에서 제공하는 데이터 분석 전용 지도입니다. 색감이 절제된 Positron(밝음), Dark Matter(어두움), Voyager 스타일을 제공하여, 위에 표현되는 데이터 포인트나 센서 정보가 더욱 돋보이도록 설계되었습니다.

OptionTypeDescription
Active Map Styles

CO2Meter: K30~

  • Manufacturer: CO2Meter
  • Measurements: CO2
  • Interfaces: I2C, UART
  • Libraries: serial (UART)
  • Manufacturer URL: Link
  • Datasheet URL: Link
OptionTypeDescription
I2C AddressTextThe address of the I2C device.
I2C BusIntegerThe Bus the I2C device is connected.
UART DeviceTextThe UART device location (e.g. /dev/ttyUSB1)
Period (Seconds)DecimalThe duration between measurements or actions
Pre OutputSelectTurn the selected output on before taking every measurement
Pre Out Duration (Seconds)DecimalIf a Pre Output is selected, set the duration to turn the Pre Output on for before every measurement is acquired.
Pre During MeasureBooleanCheck to turn the output off after (opposed to before) the measurement is complete

Catnip Electronics: Chirp~

  • Manufacturer: Catnip Electronics
  • Measurements: Light/Moisture/Temperature
  • Interfaces: I2C
  • Libraries: smbus2
  • Dependencies: smbus2
  • Manufacturer URL: Link
  • Product URL: Link
OptionTypeDescription
I2C AddressTextThe address of the I2C device.
I2C BusIntegerThe Bus the I2C device is connected.
Measurements EnabledMulti-SelectThe measurements to record
Period (Seconds)DecimalThe duration between measurements or actions
Pre OutputSelectTurn the selected output on before taking every measurement
Pre Out Duration (Seconds)DecimalIf a Pre Output is selected, set the duration to turn the Pre Output on for before every measurement is acquired.
Pre During MeasureBooleanCheck to turn the output off after (opposed to before) the measurement is complete
Commands
The I2C address can be changed. Enter a new address in the 0xYY format (e.g. 0x22, 0x50), then press Set I2C Address. Remember to deactivate and change the I2C address option after setting the new address.
New I2C AddressText - Default Value: 0x20The new I2C to set the device to
Set I2C AddressButton

ChirpStack: ChirpStack: MQTT (Payload JMESPath Expression)~

  • Manufacturer: ChirpStack
  • Measurements: Variable measurements
  • Libraries: paho-mqtt, jmespath
  • Dependencies: paho-mqtt, jmespath

ChirpStack v4 MQTT 브로커의 토픽(application/+/device/+/event/up)을 구독하여 이벤트를 수신하고, 각 이벤트 JSON에 대해 채널별 JMESPath 표현식을 적용하여 측정값을 저장합니다. 예시(https://jmespath.org): object.battery_V, object.battery_pct, max_by(rxInfo,&rssi).rssi, deviceInfo.devEui.

OptionTypeDescription
Measurements EnabledMulti-SelectThe measurements to record
Pre OutputSelectTurn the selected output on before taking every measurement
Pre Out Duration (Seconds)DecimalIf a Pre Output is selected, set the duration to turn the Pre Output on for before every measurement is acquired.
Pre During MeasureBooleanCheck to turn the output off after (opposed to before) the measurement is complete
MQTT HostText - Default Value: localhostMQTT 브로커 호스트명 또는 IP 주소 (예: localhost)
MQTT PortText - Default Value: 1883MQTT 브로커 포트 (기본 1883, TLS는 8883 권장)
MQTT UsernameText선택 사항: 브로커 인증 사용자 이름
MQTT PasswordText선택 사항: 브로커 인증 비밀번호
Enable TLSBooleanTLS(SSL) 연결 사용 여부 (기본 꺼짐)
CA Certificate PathText선택 사항: TLS 사용 시 CA 인증서 경로
Client IDText - Default Value: client_kkohqJyuUnique client ID for connecting to the server
Keepalive (sec)Text - Default Value: 60MQTT Keepalive 초 (기본 60초)
Subscribe TopicsText - Default Value: application/+/device/+/event/up콤마(,)로 구분된 구독 토픽들 (예: application/+/device/+/event/up)
QoSTextMQTT QoS 레벨 (0, 1, 2)
Device EUIs (comma-separated)Text선택 사항: 특정 디바이스만 처리. EUI를 콤마(,)로 구분해 입력
Channel Options
NameTextA name to distinguish this from others
JMESPath ExpressionText수신 이벤트 전체(JSON)에 대해 평가합니다

Chirpstack: ChirpStack: REST API (Payload JMESPath Expression)~

  • Manufacturer: Chirpstack
  • Measurements: Variable measurements
  • Libraries: chirpstack-rest-api, requests, jmespath

ChirpStack v4 REST API를 주기적으로 호출하여 디바이스 이벤트를 가져오고, 각 이벤트 JSON에 대해 채널별 JMESPath 표현식을 적용하여 측정값을 저장합니다. 예시(https://jmespath.org): object.battery_V, object.battery_pct, max_by(rxInfo,&rssi).rssi, deviceInfo.devEui.

OptionTypeDescription
Measurements EnabledMulti-SelectThe measurements to record
Period (Seconds)DecimalThe duration between measurements or actions
Start Offset (Seconds)IntegerThe duration to wait before the first operation
Pre OutputSelectTurn the selected output on before taking every measurement
Pre Out Duration (Seconds)DecimalIf a Pre Output is selected, set the duration to turn the Pre Output on for before every measurement is acquired.
Pre During MeasureBooleanCheck to turn the output off after (opposed to before) the measurement is complete
API Base URLText - Default Value: http://localhost:8090ChirpStack REST API의 기본 주소 (예: http://localhost:8080) (일반적으로 REST 프록시는 8090 포트)
API TokenTextChirpStack REST API 접근을 위한 Bearer 토큰 (관리 콘솔에서 발급)
Tenant IDText선택 사항: 특정 테넌트에 속한 디바이스만 조회할 때 사용
Application IDText선택 사항: 특정 애플리케이션에 속한 디바이스만 조회할 때 사용
Device EUIs (comma-separated)Text선택 사항: 조회할 디바이스 EUI를 콤마(,)로 구분해 입력. 비우면 애플리케이션의 모든 디바이스 대상
Page size / limitText - Default Value: 50한 번의 REST API 호출에서 가져올 이벤트 개수(페이지 크기)
Event kindText - Default Value: up가져올 이벤트의 종류 (예: up, join, status)
Fallback URL templateText - Default Value: /api/devices/{dev_eui}/events?limit={limit}&kind={kind}&after={after}공식 파이썬 클라이언트를 사용할 수 없을 때 REST 요청에 사용할 URL 템플릿 (API Base URL 뒤에 연결됨). {dev_eui}, {limit}, {kind}, {after}가 자동 치환됨
Channel Options
NameTextA name to distinguish this from others
JMESPath ExpressionTextEvaluated against the full event JSON

Cozir: Cozir CO2~

  • Manufacturer: Cozir
  • Measurements: CO2/Humidity/Temperature
  • Interfaces: UART
  • Libraries: pierre-haessig/pycozir
  • Dependencies: cozir
  • Manufacturer URL: Link
  • Datasheet URL: Link
OptionTypeDescription
UART DeviceTextThe UART device location (e.g. /dev/ttyUSB1)
Measurements EnabledMulti-SelectThe measurements to record
Period (Seconds)DecimalThe duration between measurements or actions
Pre OutputSelectTurn the selected output on before taking every measurement
Pre Out Duration (Seconds)DecimalIf a Pre Output is selected, set the duration to turn the Pre Output on for before every measurement is acquired.
Pre During MeasureBooleanCheck to turn the output off after (opposed to before) the measurement is complete

ESA: GL: Soil Moisture (NASA SMAP)~

  • Manufacturer: ESA
  • Measurements: Status
  • Libraries: gis_esa
  • Manufacturer URL: Link

유럽우주국(ESA)의 Sentinel-2 위성 데이터를 기반으로 한 전 세계 토지 피복(Land Cover) 지도입니다. 식생, 도시, 농경지, 산림, 수역 등을 10m급 고해상도로 분석하여 색상별로 확인할 수 있어 환경 분석에 유용합니다.

OptionTypeDescription
Date ModeSelect
Custom DateText

Ecowitt: Ecowitt Cloud API Weather Data~

  • Manufacturer: Ecowitt

Ecowitt Cloud API를 사용하려면 Application Key, API Key, 장치 MAC 주소를 입력하세요.

OptionTypeDescription
Measurements EnabledMulti-SelectThe measurements to record
측정 기간(초)Decimal - Default Value: 60측정 주기를 초 단위로 입력하세요.
Application KeyTextEcowitt 플랫폼에서 발급받은 Application Key를 입력하세요.
API KeyTextEcowitt 플랫폼에서 발급받은 API Key를 입력하세요.
Device MACTextEcowitt 장치의 MAC 주소를 입력하세요.
Call BackText - Default Value: all호출할 데이터 종류를 입력하세요 (예: all).

Ecowitt: Ecowitt MQTT(JSON payload)~

  • Manufacturer: Ecowitt
  • Measurements: Variable measurements
  • Interfaces: AoT
  • Libraries: paho-mqtt, jmespath
  • Dependencies: paho-mqtt, jmespath

선택된 Ecowitt 장치 유형에 따라 자동 생성된 채널을 구독하고, MQTT 토픽으로 전송되는 URL 인코딩 또는 JSON 페이로드에서 각 채널의 JMESPATH 표현식으로 값을 추출하여 데이터베이스에 저장합니다. 채널별 측정 단위와 변환 설정을 사용자 정의 옵션으로 지정할 수 있습니다.

OptionTypeDescription
Measurements EnabledMulti-SelectThe measurements to record
Period (Seconds)DecimalThe duration between measurements or actions
Ecowitt 장치Select(Options: [기상대 | 온습도 센서 | 온도 센서 | 토양 수분 센서 | 잎 센서 | 거리 측정기 | 공기질 측정기] (Default in bold)
HostText - Default Value: localhostHost or IP address
PortInteger - Default Value: 1883Host port number
TopicText - Default Value: gwThe topic to subscribe to
Keep AliveInteger - Default Value: 60Maximum amount of time between received signals. Set to 0 to disable.
Client IDText - Default Value: client_SsE838CYUnique client ID for connecting to the server
Use LoginBooleanSend login credentials
Use TLSBooleanSend login credentials using TLS
UsernameText - Default Value: userUsername for connecting to the server
PasswordTextPassword for connecting to the server. Leave blank to disable.
Use WebsocketsBooleanUse websockets to connect to the server.
Channel Options
NameTextA name to distinguish this from others
JMESPATH ExpressionTextJMESPATH expression to find value in JSON response

Ecowitt: Ecowitt soil_sensor~

  • Manufacturer: Ecowitt

Ecowitt Cloud API를 사용하려면 Application Key, API Key, 장치 MAC 주소를 입력하세요.

OptionTypeDescription
Measurements EnabledMulti-SelectThe measurements to record
측정 기간(초)Decimal - Default Value: 60측정 주기를 초 단위로 입력하세요.
Application KeyTextEcowitt 플랫폼에서 발급받은 Application Key를 입력하세요.
API KeyTextEcowitt 플랫폼에서 발급받은 API Key를 입력하세요.
Device MACTextEcowitt 장치의 MAC 주소를 입력하세요.
채널 선택Text - Default Value: 1측정할 채널을 선택하세요.

Ecowitt: Ecowitt temp and humidity sensor~

  • Manufacturer: Ecowitt

Ecowitt Cloud API를 사용하려면 Application Key, API Key, 장치 MAC 주소를 입력하세요.

OptionTypeDescription
Measurements EnabledMulti-SelectThe measurements to record
측정 기간(초)Decimal - Default Value: 60측정 주기를 초 단위로 입력하세요.
Application KeyTextEcowitt 플랫폼에서 발급받은 Application Key를 입력하세요.
API KeyTextEcowitt 플랫폼에서 발급받은 API Key를 입력하세요.
Device MACTextEcowitt 장치의 MAC 주소를 입력하세요.
채널 선택Text - Default Value: 1측정할 채널을 선택하세요.

Esri: GL: Esri World Imagery~

  • Manufacturer: Esri
  • Measurements: Status
  • Libraries: gis_esri
  • Manufacturer URL: Link

세계적인 GIS 기업 Esri의 공신력 있는 지도 서비스입니다. 선명하고 정교한 World Imagery 항공 위성 사진을 제공하여 지형의 세부 형상과 시설물을 정확하게 조망하기에 최적화되어 있습니다.

GSI: JP: GSI Maps~

  • Manufacturer: GSI
  • Measurements: Status
  • Libraries: gis_gsi
  • Manufacturer URL: Link

일본 국토지리원(GSI)에서 제공하는 고정밀 공공 지도 서비스입니다. 일본 전역의 세부적인 지형과 지명 정보를 담고 있으며, 표준 지도뿐만 아니라 담색 지도, 항공 사진 등 전문적인 레이어를 활용할 수 있습니다.

OptionTypeDescription
Map Style

Generic: Hall Flow Meter~

  • Manufacturer: Generic
  • Measurements: Flow Rate, Total Volume
  • Interfaces: GPIO
  • Libraries: pigpio
  • Dependencies: pigpio, pigpio
OptionTypeDescription
Period (Seconds)DecimalThe duration between measurements or actions
Pre OutputSelectTurn the selected output on before taking every measurement
Pre Out Duration (Seconds)DecimalIf a Pre Output is selected, set the duration to turn the Pre Output on for before every measurement is acquired.
Pre During MeasureBooleanCheck to turn the output off after (opposed to before) the measurement is complete
Pulses per LiterDecimal - Default Value: 1.0Enter the conversion factor for this meter (pulses to Liter).
Commands
Clear Total: VolumeButton

Google: GL: Google Maps~

  • Manufacturer: Google
  • Measurements: Status
  • Libraries: gis_google
  • Manufacturer URL: Link

가장 널리 사용되는 구글의 웹 지도 서비스입니다. 방대한 지리 정보를 바탕으로 Road, Satellite, Hybrid, Terrain 등 4가지 모드를 지원하며, 특히 지형의 등고와 음영을 보여주는 Terrain 지도가 우수합니다. 또한, 구글의 Geocoding API를 이용하여 주소를 좌표로 변환할 수 있습니다. API 키는 구글 개발자 콘솔에서 발급 가능합니다.

OptionTypeDescription
Google Maps API KeyText
Map Style

ISRIC: GL: SoilGrids (Global Soil Info)~

  • Manufacturer: ISRIC
  • Measurements: Status
  • Libraries: gis_isric
  • Manufacturer URL: Link

세계 토양 정보 서비스(ISRIC)에서 제공하는 글로벌 토양 특성 지도입니다. 지질학적 분석을 위한 토양 성분(점토, 모래 등), pH 수치, 탄소 함유량 등 전 세계의 지하 자원 및 환경 정보를 레이어 형태로 시각화해 줍니다.

OptionTypeDescription
Soil Property

Infineon: DPS310~

OptionTypeDescription
I2C AddressTextThe address of the I2C device.
I2C BusIntegerThe Bus the I2C device is connected.
Period (Seconds)DecimalThe duration between measurements or actions
Pre OutputSelectTurn the selected output on before taking every measurement
Pre Out Duration (Seconds)DecimalIf a Pre Output is selected, set the duration to turn the Pre Output on for before every measurement is acquired.
Pre During MeasureBooleanCheck to turn the output off after (opposed to before) the measurement is complete

KMA: KMA 단기예보~

  • Manufacturer: KMA
  • Additional URL: Link

이 모듈은 농업용 단기예보 데이터를 제공합니다. 가장 최근 발표를 기준으로 사용자가 선택한 시간 뒤의 예보 데이터를 수집합니다. API 호출 시 공공데이터포털의 서비스키를 사용하고, JSON 응답에서 기온, 최저/최고 기온, 풍속, 풍향, 하늘상태, 습도, 강수량, 강수확률, 강수형태, 신적설 데이터를 추출합니다. (API 제공은 발표시간 + 10분 이후부터 이루어집니다.)

OptionTypeDescription
Period (Seconds)DecimalThe duration between measurements or actions
Pre OutputSelectTurn the selected output on before taking every measurement
Pre Out Duration (Seconds)DecimalIf a Pre Output is selected, set the duration to turn the Pre Output on for before every measurement is acquired.
Pre During MeasureBooleanCheck to turn the output off after (opposed to before) the measurement is complete
API KeyText공공데이터포털에서 발급받은 KMA API 서비스키를 입력하세요.
nx 좌표Textnx 값을 입력하세요 (숫자).
ny 좌표Textny 값을 입력하세요 (숫자).
몇 시간 뒤 예보Select(Options: [1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 | 11 | 12] (Default in bold)몇 시간 후의 예보 데이터를 사용할지 선택하세요.
API 타임아웃(초)Integer - Default Value: 60API 응답 제한 시간을 설정하세요 (기본 60초).
API 재시도 횟수Integer - Default Value: 3HTTP 오류 발생 시 같은 발표시각을 몇 번 재시도할지 설정하세요.
API 재시도 간격(초)Decimal - Default Value: 3.0재시도 사이에 대기할 시간입니다 (기본 3초).

KMA: 기상청 고해상도 500m~

  • Manufacturer: KMA
  • Additional URL: Link

기상청 API 허브에서 무료 API 키를 발급받은 뒤, 입력 설정의 위치(위도/경도)에 따라 데이터를 요청합니다. 참고: 대한민국 기상청 API는 하루 20000회 호출이 가능하며, 1회 호출당 1개의 관측지점 데이터를 반환합니다.

OptionTypeDescription
Measurements EnabledMulti-SelectThe measurements to record
Pre OutputSelectTurn the selected output on before taking every measurement
Pre Out Duration (Seconds)DecimalIf a Pre Output is selected, set the duration to turn the Pre Output on for before every measurement is acquired.
Pre During MeasureBooleanCheck to turn the output off after (opposed to before) the measurement is complete
API KeyText기상청 API 허브에서 발급받은 API Key를 입력하세요.
측정 기간(초)Decimal - Default Value: 300측정 주기를 초 단위로 입력하세요.
Channel Options
품질검사(QC) 사용Boolean - Default Value: True명백한 이상치(예: 습도 0%, 기압 0hPa 등)를 무시하거나 보정합니다.
QC 보정 유지시간(초)Decimal - Default Value: 1800이 시간 내의 마지막 정상값으로 대체합니다.
수동 백필 기간(분)Decimal - Default Value: 1440사용자 요청 시 과거 이 기간만큼 데이터를 불러옵니다. 기본 1440분(1일).
지금 백필 실행Boolean저장 후 활성화하면 즉시 백필을 1회 수행하고 자동으로 해제됩니다.
KMA 타임스탬프 오프셋(시간)Decimal - Default Value: 9KMA 응답 시각이 로컬(KST,+9) 기준일 때 UTC로 저장하기 위해 빼줄 시간 (기본 9).
강수 계열 시계열 분리Boolean - Default Value: True강수 지표(rn_ox)와 15분 강수(rn_15m)를 서로 다른 측정명으로 기록해 충돌을 방지합니다.
QC: 0°C 허용 범위(±°C)Decimal - Default Value: 3.0직전 정상값이 0°C에서 이 범위 이내일 때만 0°C를 허용합니다. 기본 ±3°C.

KMA: 기상청 지점 데이터~

  • Manufacturer: KMA
  • Measurements: 습도/온도/기압/풍속/풍향
  • Additional URL: Link

기상청 API 허브에서 무료 API 키를 발급받고 가까운 관측지점의 STN을 입력하세요.참고: 무료 API는 하루 20000회 호출이 가능하며, 1회 호출당 1개의 관측지점 데이터를 반환합니다.

OptionTypeDescription
Measurements EnabledMulti-SelectThe measurements to record
Period (Seconds)DecimalThe duration between measurements or actions
Pre OutputSelectTurn the selected output on before taking every measurement
Pre Out Duration (Seconds)DecimalIf a Pre Output is selected, set the duration to turn the Pre Output on for before every measurement is acquired.
Pre During MeasureBooleanCheck to turn the output off after (opposed to before) the measurement is complete
API KeyTextThe API Key for this service's API
stnTextThe stn to acquire the weather data

Kakao: KO: Kakao Map~

  • Manufacturer: Kakao
  • Measurements: Status
  • Libraries: gis_kakao
  • Manufacturer URL: Link
OptionTypeDescription
Map Type

MAXIM: DS1822~

  • Manufacturer: MAXIM
  • Measurements: Temperature
  • Interfaces: 1-Wire
  • Libraries: w1thermsensor
  • Dependencies: w1thermsensor
  • Manufacturer URL: Link
  • Datasheet URL: Link
OptionTypeDescription
Period (Seconds)DecimalThe duration between measurements or actions
Pre OutputSelectTurn the selected output on before taking every measurement
Pre Out Duration (Seconds)DecimalIf a Pre Output is selected, set the duration to turn the Pre Output on for before every measurement is acquired.
Pre During MeasureBooleanCheck to turn the output off after (opposed to before) the measurement is complete
Commands
Set the resolution, precision, and response time for the sensor. This setting will be written to the EEPROM to allow persistence after power loss. The EEPROM has a limited amount of writes (>50k).
ResolutionSelectSelect the resolution for the sensor
Set ResolutionButton

MAXIM: DS1825~

  • Manufacturer: MAXIM
  • Measurements: Temperature
  • Interfaces: 1-Wire
  • Libraries: w1thermsensor
  • Dependencies: w1thermsensor
  • Manufacturer URL: Link
  • Datasheet URL: Link
OptionTypeDescription
Period (Seconds)DecimalThe duration between measurements or actions
Pre OutputSelectTurn the selected output on before taking every measurement
Pre Out Duration (Seconds)DecimalIf a Pre Output is selected, set the duration to turn the Pre Output on for before every measurement is acquired.
Pre During MeasureBooleanCheck to turn the output off after (opposed to before) the measurement is complete
Commands
Set the resolution, precision, and response time for the sensor. This setting will be written to the EEPROM to allow persistence after power loss. The EEPROM has a limited amount of writes (>50k).
ResolutionSelectSelect the resolution for the sensor
Set ResolutionButton

MAXIM: DS18B20 (ow-shell)~

  • Manufacturer: MAXIM
  • Measurements: Temperature
  • Interfaces: 1-Wire
  • Libraries: ow-shell
  • Dependencies: ow-shell, owfs
  • Manufacturer URL: Link
  • Datasheet URL: Link
  • Product URLs: Link 1, Link 2, Link 3
  • Additional URL: Link

Warning: Counterfeit DS18B20 sensors are common and can cause a host of issues. Review the Additional URL for more information about how to determine if your sensor is authentic.

OptionTypeDescription
Period (Seconds)DecimalThe duration between measurements or actions
Pre OutputSelectTurn the selected output on before taking every measurement
Pre Out Duration (Seconds)DecimalIf a Pre Output is selected, set the duration to turn the Pre Output on for before every measurement is acquired.
Pre During MeasureBooleanCheck to turn the output off after (opposed to before) the measurement is complete

MAXIM: DS18B20 (w1thermsensor)~

  • Manufacturer: MAXIM
  • Measurements: Temperature
  • Interfaces: 1-Wire
  • Libraries: w1thermsensor
  • Dependencies: w1thermsensor
  • Manufacturer URL: Link
  • Datasheet URL: Link
  • Product URLs: Link 1, Link 2, Link 3
  • Additional URL: Link

Warning: Counterfeit DS18B20 sensors are common and can cause a host of issues. Review the Additional URL for more information about how to determine if your sensor is authentic.

OptionTypeDescription
Period (Seconds)DecimalThe duration between measurements or actions
Pre OutputSelectTurn the selected output on before taking every measurement
Pre Out Duration (Seconds)DecimalIf a Pre Output is selected, set the duration to turn the Pre Output on for before every measurement is acquired.
Pre During MeasureBooleanCheck to turn the output off after (opposed to before) the measurement is complete
Temperature OffsetDecimalThe temperature offset (degrees Celsius) to apply
Commands
Set the resolution, precision, and response time for the sensor. This setting will be written to the EEPROM to allow persistence after power loss. The EEPROM has a limited amount of writes (>50k).
ResolutionSelectSelect the resolution for the sensor
Set ResolutionButton

MAXIM: DS18S20~

  • Manufacturer: MAXIM
  • Measurements: Temperature
  • Interfaces: 1-Wire
  • Libraries: w1thermsensor
  • Dependencies: w1thermsensor
  • Manufacturer URL: Link
  • Datasheet URL: Link
OptionTypeDescription
Period (Seconds)DecimalThe duration between measurements or actions
Pre OutputSelectTurn the selected output on before taking every measurement
Pre Out Duration (Seconds)DecimalIf a Pre Output is selected, set the duration to turn the Pre Output on for before every measurement is acquired.
Pre During MeasureBooleanCheck to turn the output off after (opposed to before) the measurement is complete
Commands
Set the resolution, precision, and response time for the sensor. This setting will be written to the EEPROM to allow persistence after power loss. The EEPROM has a limited amount of writes (>50k).
ResolutionSelectSelect the resolution for the sensor
Set ResolutionButton

MAXIM: DS28EA00~

  • Manufacturer: MAXIM
  • Measurements: Temperature
  • Interfaces: 1-Wire
  • Libraries: w1thermsensor
  • Dependencies: w1thermsensor
  • Manufacturer URL: Link
  • Datasheet URL: Link
OptionTypeDescription
Period (Seconds)DecimalThe duration between measurements or actions
Pre OutputSelectTurn the selected output on before taking every measurement
Pre Out Duration (Seconds)DecimalIf a Pre Output is selected, set the duration to turn the Pre Output on for before every measurement is acquired.
Pre During MeasureBooleanCheck to turn the output off after (opposed to before) the measurement is complete
Commands
Set the resolution, precision, and response time for the sensor. This setting will be written to the EEPROM to allow persistence after power loss. The EEPROM has a limited amount of writes (>50k).
ResolutionSelectSelect the resolution for the sensor
Set ResolutionButton

MAXIM: MAX31850K~

  • Manufacturer: MAXIM
  • Measurements: Temperature
  • Interfaces: 1-Wire
  • Libraries: w1thermsensor
  • Dependencies: w1thermsensor
  • Manufacturer URL: Link
  • Datasheet URL: Link
  • Product URL: Link
OptionTypeDescription
Period (Seconds)DecimalThe duration between measurements or actions
Pre OutputSelectTurn the selected output on before taking every measurement
Pre Out Duration (Seconds)DecimalIf a Pre Output is selected, set the duration to turn the Pre Output on for before every measurement is acquired.
Pre During MeasureBooleanCheck to turn the output off after (opposed to before) the measurement is complete
Commands
Set the resolution, precision, and response time for the sensor. This setting will be written to the EEPROM to allow persistence after power loss. The EEPROM has a limited amount of writes (>50k).
ResolutionSelectSelect the resolution for the sensor
Set ResolutionButton

MAXIM: MAX31855 (Gravity PT100) (smbus2)~

  • Manufacturer: MAXIM
  • Measurements: Temperature
  • Interfaces: I2C
  • Libraries: smbus2
  • Dependencies: smbus2
  • Manufacturer URL: Link
  • Datasheet URL: Link
  • Product URL: Link
OptionTypeDescription
Period (Seconds)DecimalThe duration between measurements or actions
Pre OutputSelectTurn the selected output on before taking every measurement
Pre Out Duration (Seconds)DecimalIf a Pre Output is selected, set the duration to turn the Pre Output on for before every measurement is acquired.
Pre During MeasureBooleanCheck to turn the output off after (opposed to before) the measurement is complete

MAXIM: MAX31855 (Gravity PT100) (wiringpi)~

  • Manufacturer: MAXIM
  • Measurements: Temperature
  • Interfaces: I2C
  • Libraries: wiringpi
  • Dependencies: wiringpi
  • Manufacturer URL: Link
  • Datasheet URL: Link
  • Product URL: Link
OptionTypeDescription
Period (Seconds)DecimalThe duration between measurements or actions
Pre OutputSelectTurn the selected output on before taking every measurement
Pre Out Duration (Seconds)DecimalIf a Pre Output is selected, set the duration to turn the Pre Output on for before every measurement is acquired.
Pre During MeasureBooleanCheck to turn the output off after (opposed to before) the measurement is complete

MAXIM: MAX31855 (Adafruit_MAX31855)~

  • Manufacturer: MAXIM
  • Measurements: Temperature (Object/Die)
  • Interfaces: UART
  • Libraries: Adafruit_MAX31855
  • Dependencies: Adafruit_MAX31855, Adafruit-GPIO
  • Manufacturer URL: Link
  • Datasheet URL: Link
  • Product URL: Link
OptionTypeDescription
Pin: Cable SelectIntegerGPIO (using BCM numbering): Pin: Cable Select
Measurements EnabledMulti-SelectThe measurements to record
Period (Seconds)DecimalThe duration between measurements or actions
Pre OutputSelectTurn the selected output on before taking every measurement
Pre Out Duration (Seconds)DecimalIf a Pre Output is selected, set the duration to turn the Pre Output on for before every measurement is acquired.
Pre During MeasureBooleanCheck to turn the output off after (opposed to before) the measurement is complete

MAXIM: MAX31855 (adafruit-circuitpython-max31855)~

  • Manufacturer: MAXIM
  • Measurements: Temperature (Object/Die)
  • Interfaces: SPI
  • Libraries: adafruit-circuitpython-max31855
  • Dependencies: adafruit-circuitpython-max31855
  • Manufacturer URL: Link
  • Datasheet URL: Link
  • Product URL: Link
OptionTypeDescription
Measurements EnabledMulti-SelectThe measurements to record
Period (Seconds)DecimalThe duration between measurements or actions
Pre OutputSelectTurn the selected output on before taking every measurement
Pre Out Duration (Seconds)DecimalIf a Pre Output is selected, set the duration to turn the Pre Output on for before every measurement is acquired.
Pre During MeasureBooleanCheck to turn the output off after (opposed to before) the measurement is complete
Chip Select PinInteger - Default Value: 5Enter the GPIO Chip Select Pin for your device.

MAXIM: MAX31856~

  • Manufacturer: MAXIM
  • Measurements: Temperature (Object/Die)
  • Interfaces: UART
  • Libraries: RPi.GPIO
  • Dependencies: RPi.GPIO
  • Manufacturer URL: Link
  • Datasheet URL: Link
  • Product URL: Link
OptionTypeDescription
Pin: Cable SelectIntegerGPIO (using BCM numbering): Pin: Cable Select
Measurements EnabledMulti-SelectThe measurements to record
Period (Seconds)DecimalThe duration between measurements or actions
Pre OutputSelectTurn the selected output on before taking every measurement
Pre Out Duration (Seconds)DecimalIf a Pre Output is selected, set the duration to turn the Pre Output on for before every measurement is acquired.
Pre During MeasureBooleanCheck to turn the output off after (opposed to before) the measurement is complete

MAXIM: MAX31865 (Adafruit-CircuitPython-MAX31865)~

This module was added to allow support for multiple sensors to be connected at the same time, which the original MAX31865 module was not designed for.

OptionTypeDescription
Period (Seconds)DecimalThe duration between measurements or actions
Pre OutputSelectTurn the selected output on before taking every measurement
Pre Out Duration (Seconds)DecimalIf a Pre Output is selected, set the duration to turn the Pre Output on for before every measurement is acquired.
Pre During MeasureBooleanCheck to turn the output off after (opposed to before) the measurement is complete
Chip Select PinInteger - Default Value: 8Enter the GPIO Chip Select Pin for your device.
Number of wiresSelect(Options: [2 Wires | 3 Wires | 4 Wires] (Default in bold)Select the number of wires your thermocouple has.

MAXIM: MAX31865 (RPi.GPIO)~

  • Manufacturer: MAXIM
  • Measurements: Temperature
  • Interfaces: UART
  • Libraries: RPi.GPIO
  • Dependencies: RPi.GPIO
  • Manufacturer URL: Link
  • Datasheet URL: Link
  • Product URL: Link

Note: This module does not allow for multiple sensors to be connected at the same time. For multi-sensor support, use the MAX31865 CircuitPython Input.

OptionTypeDescription
Pin: Cable SelectIntegerGPIO (using BCM numbering): Pin: Cable Select
Period (Seconds)DecimalThe duration between measurements or actions
Pre OutputSelectTurn the selected output on before taking every measurement
Pre Out Duration (Seconds)DecimalIf a Pre Output is selected, set the duration to turn the Pre Output on for before every measurement is acquired.
Pre During MeasureBooleanCheck to turn the output off after (opposed to before) the measurement is complete

MQTT: MQTT Subscribe (JSON payload)~

  • Manufacturer: MQTT
  • Measurements: Variable measurements
  • Interfaces: AoT
  • Libraries: paho-mqtt, jmespath
  • Dependencies: paho-mqtt, jmespath

A single topic is subscribed to and the returned JSON payload contains one or more key/value pairs. The given JSON Key is used as a JMESPATH expression to find the corresponding value that will be stored for that channel. Be sure you select and save the Measurement Unit for each channel. Once the unit has been saved, you can convert to other units in the Convert Measurement section. Example expressions for jmespath (https://jmespath.org) include temperature, sensors[0].temperature, and bathroom.temperature which refer to the temperature as a direct key within the first entry of sensors or as a subkey of bathroom, respectively. Jmespath elements and keys that contain special characters have to be enclosed in double quotes, e.g. "sensor-1".temperature. Warning: If using multiple MQTT Inputs or Functions, ensure the Client IDs are unique.

OptionTypeDescription
Period (Seconds)DecimalThe duration between measurements or actions
HostText - Default Value: localhostHost or IP address
PortInteger - Default Value: 1883Host port number
TopicText - Default Value: mqtt/test/inputThe topic to subscribe to
Keep AliveInteger - Default Value: 60Maximum amount of time between received signals. Set to 0 to disable.
Client IDText - Default Value: client_0Rd3a2p7Unique client ID for connecting to the server
Use LoginBooleanSend login credentials
Use TLSBooleanSend login credentials using TLS
UsernameText - Default Value: userUsername for connecting to the server
PasswordTextPassword for connecting to the server. Leave blank to disable.
Use WebsocketsBooleanUse websockets to connect to the server.
Channel Options
NameTextA name to distinguish this from others
JMESPATH ExpressionTextJMESPATH expression to find value in JSON response

MQTT: MQTT Subscribe (Value payload)~

  • Manufacturer: MQTT
  • Measurements: Variable measurements
  • Interfaces: AoT
  • Libraries: paho-mqtt
  • Dependencies: paho-mqtt

A topic is subscribed to for each channel Subscription Topic and the returned payload value will be stored for that channel. Be sure you select and save the Measurement Unit for each of the channels. Once the unit has been saved, you can convert to other units in the Convert Measurement section. Warning: If using multiple MQTT Inputs or Functions, ensure the Client IDs are unique.

OptionTypeDescription
Measurements EnabledMulti-SelectThe measurements to record
HostText - Default Value: localhostHost or IP address
PortInteger - Default Value: 1883Host port number
Keep AliveInteger - Default Value: 60Maximum amount of time between received signals. Set to 0 to disable.
Client IDText - Default Value: client_oLmvWD4kUnique client ID for connecting to the server
Use LoginBooleanSend login credentials
Use TLSBooleanSend login credentials using TLS
UsernameText - Default Value: userUsername for connecting to the server
PasswordTextPassword for connecting to the server. Leave blank to disable.
Use WebsocketsBooleanUse websockets to connect to the server.
Channel Options
NameTextA name to distinguish this from others
Subscription TopicTextThe MQTT topic to subscribe to

Mapbox: GL: Mapbox~

  • Manufacturer: Mapbox
  • Measurements: Status
  • Libraries: gis_mapbox
  • Manufacturer URL: Link

세련된 디자인과 커스터마이징이 강점인 맵박스의 벡터 및 타일 지도입니다. Streets, Satellite, Dark, Light 스타일을 지원하며, 렌더링 성능이 매우 우수하여 부드러운 지도 조작 환경을 제공합니다.

OptionTypeDescription
Mapbox Access TokenText
Map Style

Melexis: MLX90393~

OptionTypeDescription
I2C AddressTextThe address of the I2C device.
I2C BusIntegerThe Bus the I2C device is connected.
Period (Seconds)DecimalThe duration between measurements or actions
Pre OutputSelectTurn the selected output on before taking every measurement
Pre Out Duration (Seconds)DecimalIf a Pre Output is selected, set the duration to turn the Pre Output on for before every measurement is acquired.
Pre During MeasureBooleanCheck to turn the output off after (opposed to before) the measurement is complete

Melexis: MLX90614~

  • Manufacturer: Melexis
  • Measurements: Temperature (Ambient/Object)
  • Interfaces: I2C
  • Libraries: smbus2
  • Dependencies: smbus2
  • Manufacturer URL: Link
  • Datasheet URL: Link
  • Product URL: Link
OptionTypeDescription
I2C AddressTextThe address of the I2C device.
I2C BusIntegerThe Bus the I2C device is connected.
Measurements EnabledMulti-SelectThe measurements to record
Period (Seconds)DecimalThe duration between measurements or actions
Pre OutputSelectTurn the selected output on before taking every measurement
Pre Out Duration (Seconds)DecimalIf a Pre Output is selected, set the duration to turn the Pre Output on for before every measurement is acquired.
Pre During MeasureBooleanCheck to turn the output off after (opposed to before) the measurement is complete

Microchip: MCP3008 (Adafruit_CircuitPython_MCP3xxx)~

  • Manufacturer: Microchip
  • Measurements: Voltage (Analog-to-Digital Converter)
  • Interfaces: UART
  • Libraries: Adafruit_CircuitPython_MCP3xxx
  • Dependencies: adafruit-circuitpython-mcp3xxx
  • Manufacturer URL: Link
  • Datasheet URL: Link
  • Product URL: Link
OptionTypeDescription
Pin: Cable SelectIntegerGPIO (using BCM numbering): Pin: Cable Select
Measurements EnabledMulti-SelectThe measurements to record
Period (Seconds)DecimalThe duration between measurements or actions
Pre OutputSelectTurn the selected output on before taking every measurement
Pre Out Duration (Seconds)DecimalIf a Pre Output is selected, set the duration to turn the Pre Output on for before every measurement is acquired.
Pre During MeasureBooleanCheck to turn the output off after (opposed to before) the measurement is complete
VREF (volts)Decimal - Default Value: 3.3Set the VREF voltage

Microchip: MCP3008 (Adafruit_MCP3008)~

  • Manufacturer: Microchip
  • Measurements: Voltage (Analog-to-Digital Converter)
  • Interfaces: UART
  • Libraries: Adafruit_MCP3008
  • Dependencies: Adafruit-MCP3008
  • Manufacturer URL: Link
  • Datasheet URL: Link
  • Product URL: Link
OptionTypeDescription
Pin: Cable SelectIntegerGPIO (using BCM numbering): Pin: Cable Select
Measurements EnabledMulti-SelectThe measurements to record
Period (Seconds)DecimalThe duration between measurements or actions
Pre OutputSelectTurn the selected output on before taking every measurement
Pre Out Duration (Seconds)DecimalIf a Pre Output is selected, set the duration to turn the Pre Output on for before every measurement is acquired.
Pre During MeasureBooleanCheck to turn the output off after (opposed to before) the measurement is complete
VREF (volts)Decimal - Default Value: 3.3Set the VREF voltage

Microchip: MCP3208~

  • Manufacturer: Microchip
  • Measurements: Voltage (Analog-to-Digital Converter)
  • Interfaces: SPI
  • Libraries: MCP3208
  • Dependencies: Adafruit-GPIO
  • Manufacturer URL: Link
  • Datasheet URL: Link
OptionTypeDescription
Pin: Cable SelectIntegerGPIO (using BCM numbering): Pin: Cable Select
Measurements EnabledMulti-SelectThe measurements to record
Period (Seconds)DecimalThe duration between measurements or actions
Pre OutputSelectTurn the selected output on before taking every measurement
Pre Out Duration (Seconds)DecimalIf a Pre Output is selected, set the duration to turn the Pre Output on for before every measurement is acquired.
Pre During MeasureBooleanCheck to turn the output off after (opposed to before) the measurement is complete
SPI BusIntegerThe SPI bus ID.
SPI DeviceIntegerThe SPI device ID.
VREF (volts)Decimal - Default Value: 3.3Set the VREF voltage

Microchip: MCP342x (x=2,3,4,6,7,8)~

OptionTypeDescription
I2C AddressTextThe address of the I2C device.
I2C BusIntegerThe Bus the I2C device is connected.
Measurements EnabledMulti-SelectThe measurements to record
Period (Seconds)DecimalThe duration between measurements or actions
Pre OutputSelectTurn the selected output on before taking every measurement
Pre Out Duration (Seconds)DecimalIf a Pre Output is selected, set the duration to turn the Pre Output on for before every measurement is acquired.
Pre During MeasureBooleanCheck to turn the output off after (opposed to before) the measurement is complete

Microchip: MCP9808~

OptionTypeDescription
I2C AddressTextThe address of the I2C device.
I2C BusIntegerThe Bus the I2C device is connected.
Period (Seconds)DecimalThe duration between measurements or actions
Pre OutputSelectTurn the selected output on before taking every measurement
Pre Out Duration (Seconds)DecimalIf a Pre Output is selected, set the duration to turn the Pre Output on for before every measurement is acquired.
Pre During MeasureBooleanCheck to turn the output off after (opposed to before) the measurement is complete

Microsoft: GL: Bing Maps~

  • Manufacturer: Microsoft
  • Measurements: Status
  • Libraries: gis_bing
  • Manufacturer URL: Link

마이크로소프트의 글로벌 지도 서비스입니다. 고해상도 항공 사진(Aerial)과 이름이 포함된 항공 사진(Hybrid)을 제공하며, MS만의 깨끗하고 정밀한 도로 지도를 활용할 수 있는 장점이 있습니다.

OptionTypeDescription
Bing Maps API KeyText
Map Style

Multiple Manufacturers: HC-SR04~

OptionTypeDescription
Period (Seconds)DecimalThe duration between measurements or actions
Pre OutputSelectTurn the selected output on before taking every measurement
Pre Out Duration (Seconds)DecimalIf a Pre Output is selected, set the duration to turn the Pre Output on for before every measurement is acquired.
Pre During MeasureBooleanCheck to turn the output off after (opposed to before) the measurement is complete
Trigger PinIntegerEnter the GPIO Trigger Pin for your device (BCM numbering).
Echo PinIntegerEnter the GPIO Echo Pin for your device (BCM numbering).

NASA: NASA GIBS~

  • Manufacturer: NASA
  • Measurements: Status
  • Interfaces: AoT
  • Libraries: gis_nasa_gibs
  • Manufacturer URL: Link

미국 항공우주국(NASA)의 위성 관측 시스템(GIBS)을 통해 수집된 실시간 지구 관측 지도입니다. 위성 사진(Blue Marble)뿐만 아니라 기온, 구름, 화재 등 환경 관련 데이터를 날짜별로 선택하여 시계열 분석이 가능합니다.

OptionTypeDescription
Satellite Layer
Date ModeSelect
Custom DateText
  • Manufacturer: Naver
  • Measurements: Status
  • Libraries: gis_naver
  • Manufacturer URL: Link
OptionTypeDescription
Map Type

OpenStreetMap: GL: OpenStreetMap~

  • Manufacturer: OpenStreetMap
  • Measurements: Status
  • Libraries: gis_osm
  • Manufacturer URL: Link

전 세계 사용자들이 협업하여 만든 위키피디아 방식의 자유 지도 데이터입니다. 무료로 사용 가능하며, 전 세계 도로와 건물 정보가 꾸준히 업데이트되는 활발한 커뮤니티 성격의 표준 웹 지도입니다.

OpenTopoMap: GL: OpenTopoMap~

  • Manufacturer: OpenTopoMap
  • Measurements: Status
  • Libraries: gis_opentopomap
  • Manufacturer URL: Link

OpenStreetMap 데이터를 기반으로 등고선과 지형 음영을 강조한 지형도 서비스입니다. 산악 지형이나 경사면 분석 시 구분이 명확하며 가독성이 높아 등산이나 야외 활동 관련 시각화에 적합합니다.

OpenWeather: OpenWeatherMap (City/Coords, Current)~

  • Manufacturer: OpenWeather
  • Measurements: Humidity/Temperature/Pressure/Wind
  • Additional URL: Link

Obtain a free API key at openweathermap.org. Enter a City OR Latitude/Longitude coordinates. Note: the free API subscription is limited to 60 calls per minute

OptionTypeDescription
Measurements EnabledMulti-SelectThe measurements to record
Period (Seconds)DecimalThe duration between measurements or actions
Pre OutputSelectTurn the selected output on before taking every measurement
Pre Out Duration (Seconds)DecimalIf a Pre Output is selected, set the duration to turn the Pre Output on for before every measurement is acquired.
Pre During MeasureBooleanCheck to turn the output off after (opposed to before) the measurement is complete
API KeyTextThe API Key for this service's API
CityTextCity Name (Optional if using Coords)

OpenWeather: OpenWeatherMap (Lat/Lon, Current/Future)~

  • Manufacturer: OpenWeather
  • Measurements: Humidity/Temperature/Pressure/Wind
  • Interfaces: AoT
  • Additional URL: Link

Obtain a free API key at openweathermap.org. Notes: The free API subscription is limited to 60 calls per minute. If a Day (Future) time is selected, Minimum and Maximum temperatures are available as measurements.

OptionTypeDescription
Measurements EnabledMulti-SelectThe measurements to record
Period (Seconds)DecimalThe duration between measurements or actions
Pre OutputSelectTurn the selected output on before taking every measurement
Pre Out Duration (Seconds)DecimalIf a Pre Output is selected, set the duration to turn the Pre Output on for before every measurement is acquired.
Pre During MeasureBooleanCheck to turn the output off after (opposed to before) the measurement is complete
API KeyTextThe API Key for this service's API
TimeSelect(Options: [Current (Present) | 1 Day (Future) | 2 Day (Future) | 3 Day (Future) | 4 Day (Future) | 5 Day (Future) | 6 Day (Future) | 7 Day (Future) | 1 Hour (Future) | 2 Hours (Future) | 3 Hours (Future) | 4 Hours (Future) | 5 Hours (Future) | 6 Hours (Future) | 7 Hours (Future) | 8 Hours (Future) | 9 Hours (Future) | 10 Hours (Future) | 11 Hours (Future) | 12 Hours (Future) | 13 Hours (Future) | 14 Hours (Future) | 15 Hours (Future) | 16 Hours (Future) | 17 Hours (Future) | 18 Hours (Future) | 19 Hours (Future) | 20 Hours (Future) | 21 Hours (Future) | 22 Hours (Future) | 23 Hours (Future) | 24 Hours (Future) | 25 Hours (Future) | 26 Hours (Future) | 27 Hours (Future) | 28 Hours (Future) | 29 Hours (Future) | 30 Hours (Future) | 31 Hours (Future) | 32 Hours (Future) | 33 Hours (Future) | 34 Hours (Future) | 35 Hours (Future) | 36 Hours (Future) | 37 Hours (Future) | 38 Hours (Future) | 39 Hours (Future) | 40 Hours (Future) | 41 Hours (Future) | 42 Hours (Future) | 43 Hours (Future) | 44 Hours (Future) | 45 Hours (Future) | 46 Hours (Future) | 47 Hours (Future) | 48 Hours (Future)] (Default in bold)Select the time for the current or forecast weather

OpenWeatherMap: GL: OpenWeatherMap~

  • Manufacturer: OpenWeatherMap
  • Measurements: Status
  • Libraries: gis_openweather
  • Manufacturer URL: Link

전 세계 날씨 정보를 지도에 중첩하여 보여주는 기상 전문 서비스입니다. 구름, 강수량, 기온, 풍속, 기압 및 레이더 정보를 실시간으로 제공하여 현재 기상 상황을 직관적으로 파악할 수 있게 돕습니다.

OptionTypeDescription
API KeyText
Active Layers

Panasonic: AMG8833~

OptionTypeDescription
I2C AddressTextThe address of the I2C device.
I2C BusIntegerThe Bus the I2C device is connected.
Measurements EnabledMulti-SelectThe measurements to record
Period (Seconds)DecimalThe duration between measurements or actions
Pre OutputSelectTurn the selected output on before taking every measurement
Pre Out Duration (Seconds)DecimalIf a Pre Output is selected, set the duration to turn the Pre Output on for before every measurement is acquired.
Pre During MeasureBooleanCheck to turn the output off after (opposed to before) the measurement is complete

Power Monitor: RPi 6-Channel Power Monitor (v0.1.0)~

  • Manufacturer: Power Monitor
  • Measurements: AC Voltage, Power, Current, Power Factor
  • Libraries: rpi-power-monitor
  • Dependencies: rpi_power_monitor
  • Manufacturer URL: Link
  • Product URL: Link

See https://github.com/David00/rpi-power-monitor/wiki/Calibrating-for-Accuracy for calibration procedures.

OptionTypeDescription
Measurements EnabledMulti-SelectThe measurements to record
Period (Seconds)DecimalThe duration between measurements or actions
Pre OutputSelectTurn the selected output on before taking every measurement
Pre Out Duration (Seconds)DecimalIf a Pre Output is selected, set the duration to turn the Pre Output on for before every measurement is acquired.
Pre During MeasureBooleanCheck to turn the output off after (opposed to before) the measurement is complete
Grid VoltageDecimal - Default Value: 124.2The AC voltage measured at the outlet
Transformer VoltageDecimal - Default Value: 10.2The AC voltage measured at the barrel plug of the 9 VAC transformer
CT1 Phase CorrectionDecimal - Default Value: 1.0The phase correction value for CT1
CT2 Phase CorrectionDecimal - Default Value: 1.0The phase correction value for CT2
CT3 Phase CorrectionDecimal - Default Value: 1.0The phase correction value for CT3
CT4 Phase CorrectionDecimal - Default Value: 1.0The phase correction value for CT4
CT5 Phase CorrectionDecimal - Default Value: 1.0The phase correction value for CT5
CT6 Phase CorrectionDecimal - Default Value: 1.0The phase correction value for CT6
CT1 Accuracy CalibrationDecimal - Default Value: 1.0The accuracy calibration value for CT1
CT2 Accuracy CalibrationDecimal - Default Value: 1.0The accuracy calibration value for CT2
CT3 Accuracy CalibrationDecimal - Default Value: 1.0The accuracy calibration value for CT3
CT4 Accuracy CalibrationDecimal - Default Value: 1.0The accuracy calibration value for CT4
CT5 Accuracy CalibrationDecimal - Default Value: 1.0The accuracy calibration value for CT5
CT6 Accuracy CalibrationDecimal - Default Value: 1.0The accuracy calibration value for CT6
AC Accuracy CalibrationDecimal - Default Value: 1.0The accuracy calibration value for AC

Power Monitor: RPi 6-Channel Power Monitor (v0.4.0)~

  • Manufacturer: Power Monitor
  • Measurements: AC Voltage, Power, Energy, Current, Power Factor
  • Libraries: rpi-power-monitor
  • Dependencies: rpi_power_monitor
  • Manufacturer URL: Link
  • Product URL: Link

See https://david00.github.io/rpi-power-monitor/docs/v0.3.0/calibration.html for calibration documentation.

OptionTypeDescription
Measurements EnabledMulti-SelectThe measurements to record
Period (Seconds)DecimalThe duration between measurements or actions
Pre OutputSelectTurn the selected output on before taking every measurement
Pre Out Duration (Seconds)DecimalIf a Pre Output is selected, set the duration to turn the Pre Output on for before every measurement is acquired.
Pre During MeasureBooleanCheck to turn the output off after (opposed to before) the measurement is complete
Period (Seconds) for kWh MeasuringInteger - Default Value: 5How often to acquire measurements to calculate kWh
Grid VoltageDecimal - Default Value: 124.2The AC voltage measured at the outlet
Transformer VoltageDecimal - Default Value: 10.2The AC voltage measured at the barrel plug of the 9 VAC transformer
AC Frequency (Hz)Integer - Default Value: 60The frequency of the AC voltage
CT1 CalibrationDecimal - Default Value: 1.0The calibration value for CT1
CT1 RatingDecimal - Default Value: 100The Amp rating for the CT1 clamp
CT2 CalibrationDecimal - Default Value: 1.0The calibration value for CT2
CT2 RatingDecimal - Default Value: 100The Amp rating for the CT2 clamp
CT3 CalibrationDecimal - Default Value: 1.0The calibration value for CT3
CT3 RatingDecimal - Default Value: 100The Amp rating for the CT3 clamp
CT4 CalibrationDecimal - Default Value: 1.0The calibration value for CT4
CT4 RatingDecimal - Default Value: 100The Amp rating for the CT4 clamp
CT5 CalibrationDecimal - Default Value: 1.0The calibration value for CT5
CT5 RatingDecimal - Default Value: 100The Amp rating for the CT5 clamp
CT6 CalibrationDecimal - Default Value: 1.0The calibration value for CT6
CT6 RatingDecimal - Default Value: 100The Amp rating for the CT6 clamp
AC CalibrationDecimal - Default Value: 1.0The calibration value for AC
Commands
Clear the running kWh totals.
Channel to ClearSelect(Options: [All Channels | Channel 1 | Channel 2 | Channel 3 | Channel 4 | Channel 5 | Channel 6] (Default in bold)The channel(s) to clear the kWh total and start back at 0.
Clear kWh TotalButton

ROHM: BH1750~

  • Manufacturer: ROHM
  • Measurements: Light
  • Interfaces: I2C
  • Libraries: smbus2
  • Dependencies: smbus2
  • Datasheet URL: Link
  • Product URL: Link
OptionTypeDescription
I2C AddressTextThe address of the I2C device.
I2C BusIntegerThe Bus the I2C device is connected.
Period (Seconds)DecimalThe duration between measurements or actions
Pre OutputSelectTurn the selected output on before taking every measurement
Pre Out Duration (Seconds)DecimalIf a Pre Output is selected, set the duration to turn the Pre Output on for before every measurement is acquired.
Pre During MeasureBooleanCheck to turn the output off after (opposed to before) the measurement is complete

RainViewer: GL: RainViewer (Radar) [Discontinued]~

  • Manufacturer: RainViewer
  • Measurements: Status
  • Libraries: gis_rainviewer
  • Manufacturer URL: Link

[Service Discontinued / 서비스 중단 안내] RainViewer의 Radar API 서비스가 2026년 1월 31일부로 종료되었습니다. 현재 이 레이어의 실시간 데이터 수신은 불가능합니다. 대안으로 OpenWeatherMap (Radar) 레이어 사용을 권장합니다.

OptionTypeDescription
API KeyText
Color SchemeSelect
SmoothingBoolean

Raspberry Pi Foundation: Sense HAT~

  • Manufacturer: Raspberry Pi Foundation
  • Measurements: hum/temp/press/compass/magnet/accel/gyro
  • Interfaces: I2C
  • Libraries: sense-hat
  • Dependencies: git, Bash Commands (see Module for details), sense-hat
  • Manufacturer URL: Link

This module acquires measurements from the Raspberry Pi Sense HAT sensors, which include the LPS25H, LSM9DS1, and HTS221.

OptionTypeDescription
Measurements EnabledMulti-SelectThe measurements to record
Period (Seconds)DecimalThe duration between measurements or actions
Pre OutputSelectTurn the selected output on before taking every measurement
Pre Out Duration (Seconds)DecimalIf a Pre Output is selected, set the duration to turn the Pre Output on for before every measurement is acquired.
Pre During MeasureBooleanCheck to turn the output off after (opposed to before) the measurement is complete

Remote Sensing: Satellite Analysis~

  • Manufacturer: Remote Sensing
  • Measurements: Analysis Channels
  • Interfaces: AoT
  • Libraries: requests

Collects environmental data from satellite analysis and GIS layers based on the device location. Supports auto-adjustment for data gaps (e.g. coastal areas).

OptionTypeDescription
Measurements EnabledMulti-SelectThe measurements to record
Period (Seconds)DecimalThe duration between measurements or actions
Active GIS SourceSelectSelect the satellite/GIS analysis source.
Auto-adjust LocationBoolean - Default Value: TrueAutomatically search nearby valid coordinates if data is missing at the exact location (Spiral Search).

Ruuvi: RuuviTag~

OptionTypeDescription
Bluetooth MAC (XX:XX:XX:XX:XX:XX)TextThe Hci location of the Bluetooth device.
Bluetooth Adapter (hci[X])TextThe adapter of the Bluetooth device.
Measurements EnabledMulti-SelectThe measurements to record
Period (Seconds)DecimalThe duration between measurements or actions
Pre OutputSelectTurn the selected output on before taking every measurement
Pre Out Duration (Seconds)DecimalIf a Pre Output is selected, set the duration to turn the Pre Output on for before every measurement is acquired.
Pre During MeasureBooleanCheck to turn the output off after (opposed to before) the measurement is complete

STMicroelectronics: VL53L0X~

  • Manufacturer: STMicroelectronics
  • Measurements: Millimeter (Time-of-Flight Distance)
  • Interfaces: I2C
  • Libraries: VL53L0X_rasp_python
  • Dependencies: VL53L0X
  • Manufacturer URL: Link
  • Datasheet URL: Link
  • Product URLs: Link 1, Link 2
OptionTypeDescription
I2C AddressTextThe address of the I2C device.
I2C BusIntegerThe Bus the I2C device is connected.
Measurements EnabledMulti-SelectThe measurements to record
Period (Seconds)DecimalThe duration between measurements or actions
Pre OutputSelectTurn the selected output on before taking every measurement
Pre Out Duration (Seconds)DecimalIf a Pre Output is selected, set the duration to turn the Pre Output on for before every measurement is acquired.
Pre During MeasureBooleanCheck to turn the output off after (opposed to before) the measurement is complete
AccuracySelect(Options: [Good Accuracy (33 ms, 1.2 m range) | Better Accuracy (66 ms, 1.2 m range) | Best Accuracy (200 ms, 1.2 m range) | Long Range (33 ms, 2 m) | High Speed, Low Accuracy (20 ms, 1.2 m)] (Default in bold)Set the accuracy. A longer measurement duration yields a more accurate measurement
Commands
New I2C AddressText - Default Value: 0x52The new I2C to set the device to
Set I2C AddressButton

STMicroelectronics: VL53L1X~

  • Manufacturer: STMicroelectronics
  • Measurements: Millimeter (Time-of-Flight Distance)
  • Interfaces: I2C
  • Libraries: VL53L1X
  • Dependencies: smbus2, vl53l1x
  • Manufacturer URL: Link
  • Datasheet URL: Link
  • Product URLs: Link 1, Link 2

Notes when setting a custom timing budget: A higher timing budget results in greater measurement accuracy, but also a higher power consumption. The inter measurement period must be >= the timing budget, otherwise it will be double the expected value.

OptionTypeDescription
I2C AddressTextThe address of the I2C device.
I2C BusIntegerThe Bus the I2C device is connected.
Measurements EnabledMulti-SelectThe measurements to record
Period (Seconds)DecimalThe duration between measurements or actions
Pre OutputSelectTurn the selected output on before taking every measurement
Pre Out Duration (Seconds)DecimalIf a Pre Output is selected, set the duration to turn the Pre Output on for before every measurement is acquired.
Pre During MeasureBooleanCheck to turn the output off after (opposed to before) the measurement is complete
RangeSelect(Options: [Short Range | Medium Range | Long Range | Custom Timing Budget] (Default in bold)Select a range or select to set a custom Timing Budget and Inter Measurement Period.
Timing Budget (microseconds)Integer - Default Value: 66000Set the timing budget. Must be less than or equal to the Inter Measurement Period.
Inter Measurement Period (milliseconds)Integer - Default Value: 70Set the Inter Measurement Period

STMicroelectronics: VL53L4CD~

OptionTypeDescription
I2C AddressTextThe address of the I2C device.
I2C BusIntegerThe Bus the I2C device is connected.
Measurements EnabledMulti-SelectThe measurements to record
Period (Seconds)DecimalThe duration between measurements or actions
Pre OutputSelectTurn the selected output on before taking every measurement
Pre Out Duration (Seconds)DecimalIf a Pre Output is selected, set the duration to turn the Pre Output on for before every measurement is acquired.
Pre During MeasureBooleanCheck to turn the output off after (opposed to before) the measurement is complete
Timing Budget (ms)Integer - Default Value: 50Set the timing budget between 10 to 200 ms. A longer duration yields a more accurate measurement.
Inter-Measurement Period (ms)IntegerValid range between Timing Budget and 5000 ms (0 to disable)
Commands
The I2C address of the sensor can be changed. Enter a new address in the 0xYY format (e.g. 0x22, 0x50), then press Set I2C Address. Remember to deactivate the Input and change the I2C address option after setting the new address.
New I2C AddressText - Default Value: 0x29The new I2C to set the device to
Set I2C AddressButton

Seeedstudio: DHT11/22~

Enter the Grove Pi+ GPIO pin connected to the sensor and select the sensor type.

OptionTypeDescription
Measurements EnabledMulti-SelectThe measurements to record
Period (Seconds)DecimalThe duration between measurements or actions
Sensor TypeSelect(Options: [DHT11 (Blue) | DHT22 (White)] (Default in bold)Sensor type

Senseair: K96~

  • Manufacturer: Senseair
  • Measurements: Methane/Moisture/CO2/Pressure/Humidity/Temperature
  • Interfaces: UART
  • Libraries: Serial
OptionTypeDescription
UART DeviceTextThe UART device location (e.g. /dev/ttyUSB1)
Measurements EnabledMulti-SelectThe measurements to record
Period (Seconds)DecimalThe duration between measurements or actions
Pre OutputSelectTurn the selected output on before taking every measurement
Pre Out Duration (Seconds)DecimalIf a Pre Output is selected, set the duration to turn the Pre Output on for before every measurement is acquired.
Pre During MeasureBooleanCheck to turn the output off after (opposed to before) the measurement is complete

Sensirion: SCD-4x (40, 41)~

OptionTypeDescription
I2C AddressTextThe address of the I2C device.
I2C BusIntegerThe Bus the I2C device is connected.
Measurements EnabledMulti-SelectThe measurements to record
Period (Seconds)DecimalThe duration between measurements or actions
Pre OutputSelectTurn the selected output on before taking every measurement
Pre Out Duration (Seconds)DecimalIf a Pre Output is selected, set the duration to turn the Pre Output on for before every measurement is acquired.
Pre During MeasureBooleanCheck to turn the output off after (opposed to before) the measurement is complete
Temperature OffsetDecimal - Default Value: 4.0Set the sensor temperature offset
Altitude (m)IntegerSet the sensor altitude (meters)
Automatic Self-CalibrationBooleanSet the sensor automatic self-calibration
Persist SettingsBoolean - Default Value: TrueSettings will persist after powering off
Commands
You can force the CO2 calibration for a specific CO2 concentration value (in ppmv). The sensor needs to be active for at least 3 minutes prior to calibration.
CO2 Concentration (ppmv)Decimal - Default Value: 400.0Calibrate to this CO2 concentration that the sensor is being exposed to (in ppmv)
Calibrate CO2Button

Sensirion: SCD30 (Adafruit_CircuitPython_SCD30)~

OptionTypeDescription
I2C AddressTextThe address of the I2C device.
I2C BusIntegerThe Bus the I2C device is connected.
Measurements EnabledMulti-SelectThe measurements to record
Period (Seconds)DecimalThe duration between measurements or actions
Pre OutputSelectTurn the selected output on before taking every measurement
Pre Out Duration (Seconds)DecimalIf a Pre Output is selected, set the duration to turn the Pre Output on for before every measurement is acquired.
Pre During MeasureBooleanCheck to turn the output off after (opposed to before) the measurement is complete
I2C Frequency: The SCD-30 has temperamental I2C with clock stretching. The datasheet recommends starting at 50,000 Hz.
I2C Frequency (Hz)Integer - Default Value: 50000
Automatic Self Ccalibration (ASC): To work correctly, the sensor must be on and active for 7 days after enabling ASC, and exposed to fresh air for at least 1 hour per day. Consult the manufacturer’s documentation for more information.
Enable Automatic Self CalibrationBoolean
Temperature Offset: Specifies the offset to be added to the reported measurements to account for a bias in the measured signal. Must be a positive value, and will reduce the recorded temperature by that amount. Give the sensor adequate time to acclimate after setting this value. Value is in degrees Celsius with a resolution of 0.01 degrees and a maximum value of 655.35 C.
Temperature OffsetDecimal
Ambient Air Pressure (mBar): Specify the ambient air pressure at the measurement location in mBar. Setting this value adjusts the CO2 measurement calculations to account for the air pressure’s effect on readings. Values must be in mBar, from 700 to 1200 mBar.
Ambient Air Pressure (mBar)Integer - Default Value: 1200
Altitude: Specifies the altitude at the measurement location in meters above sea level. Setting this value adjusts the CO2 measurement calculations to account for the air pressure’s effect on readings.
Altitude (m)Integer - Default Value: 100
Commands
A soft reset restores factory default values.
Soft ResetButton
Forced Re-Calibration: The SCD-30 is placed in an environment with a known CO2 concentration, this concentration value is entered in the CO2 Concentration (ppmv) field, then the Foce Calibration button is pressed. But how do you come up with that known value? That is a caveat of this approach and Sensirion suggests three approaches: 1. Using a separate secondary calibrated CO2 sensor to provide the value. 2. Exposing the SCD-30 to a controlled environment with a known value. 3. Exposing the SCD-30 to fresh outside air and using a value of 400 ppm.
CO2 Concentration (ppmv)Integer - Default Value: 800The CO2 concentration of the sensor environment when forcing calibration
Force RecalibrationButton

Sensirion: SCD30 (scd30_i2c)~

  • Manufacturer: Sensirion
  • Measurements: CO2/Humidity/Temperature
  • Interfaces: I2C
  • Libraries: scd30_i2c
  • Dependencies: scd30-i2c
  • Manufacturer URL: Link
  • Datasheet URL: Link
  • Product URLs: Link 1, Link 2
OptionTypeDescription
I2C AddressTextThe address of the I2C device.
I2C BusIntegerThe Bus the I2C device is connected.
Measurements EnabledMulti-SelectThe measurements to record
Period (Seconds)DecimalThe duration between measurements or actions
Pre OutputSelectTurn the selected output on before taking every measurement
Pre Out Duration (Seconds)DecimalIf a Pre Output is selected, set the duration to turn the Pre Output on for before every measurement is acquired.
Pre During MeasureBooleanCheck to turn the output off after (opposed to before) the measurement is complete
Automatic Self Ccalibration (ASC): To work correctly, the sensor must be on and active for 7 days after enabling ASC, and exposed to fresh air for at least 1 hour per day. Consult the manufacturer’s documentation for more information.
Enable Automatic Self CalibrationBoolean
Commands
A soft reset restores factory default values.
Soft ResetButton

Sensirion: SHT1x/7x~

  • Manufacturer: Sensirion
  • Measurements: Humidity/Temperature
  • Interfaces: GPIO
  • Libraries: sht_sensor
  • Dependencies: sht-sensor
  • Manufacturer URLs: Link 1, Link 2
OptionTypeDescription
Measurements EnabledMulti-SelectThe measurements to record
Period (Seconds)DecimalThe duration between measurements or actions
Pre OutputSelectTurn the selected output on before taking every measurement
Pre Out Duration (Seconds)DecimalIf a Pre Output is selected, set the duration to turn the Pre Output on for before every measurement is acquired.
Pre During MeasureBooleanCheck to turn the output off after (opposed to before) the measurement is complete

Sensirion: SHT2x (sht20)~

  • Manufacturer: Sensirion
  • Measurements: Humidity/Temperature
  • Interfaces: I2C
  • Libraries: sht20
  • Dependencies: sht20
  • Manufacturer URL: Link
OptionTypeDescription
Measurements EnabledMulti-SelectThe measurements to record
Period (Seconds)DecimalThe duration between measurements or actions
Pre OutputSelectTurn the selected output on before taking every measurement
Pre Out Duration (Seconds)DecimalIf a Pre Output is selected, set the duration to turn the Pre Output on for before every measurement is acquired.
Pre During MeasureBooleanCheck to turn the output off after (opposed to before) the measurement is complete
Temperature ResolutionSelect(Options: [11-bit | 12-bit | 13-bit | 14-bit] (Default in bold)The resolution of the temperature measurement

Sensirion: SHT2x (smbus2)~

  • Manufacturer: Sensirion
  • Measurements: Humidity/Temperature
  • Interfaces: I2C
  • Libraries: smbus2
  • Dependencies: smbus2
  • Manufacturer URL: Link
OptionTypeDescription
Measurements EnabledMulti-SelectThe measurements to record
Period (Seconds)DecimalThe duration between measurements or actions
Pre OutputSelectTurn the selected output on before taking every measurement
Pre Out Duration (Seconds)DecimalIf a Pre Output is selected, set the duration to turn the Pre Output on for before every measurement is acquired.
Pre During MeasureBooleanCheck to turn the output off after (opposed to before) the measurement is complete

Sensirion: SHT31-D~

OptionTypeDescription
I2C AddressTextThe address of the I2C device.
I2C BusIntegerThe Bus the I2C device is connected.
Measurements EnabledMulti-SelectThe measurements to record
Period (Seconds)DecimalThe duration between measurements or actions
Pre OutputSelectTurn the selected output on before taking every measurement
Pre Out Duration (Seconds)DecimalIf a Pre Output is selected, set the duration to turn the Pre Output on for before every measurement is acquired.
Pre During MeasureBooleanCheck to turn the output off after (opposed to before) the measurement is complete
Temperature OffsetDecimalThe temperature offset (degrees Celsius) to apply

Sensirion: SHT3x (30, 31, 35)~

  • Manufacturer: Sensirion
  • Measurements: Humidity/Temperature
  • Interfaces: I2C
  • Libraries: Adafruit_SHT31
  • Dependencies: Adafruit-GPIO, Adafruit-SHT31
  • Manufacturer URL: Link
OptionTypeDescription
I2C AddressTextThe address of the I2C device.
I2C BusIntegerThe Bus the I2C device is connected.
Measurements EnabledMulti-SelectThe measurements to record
Period (Seconds)DecimalThe duration between measurements or actions
Pre OutputSelectTurn the selected output on before taking every measurement
Pre Out Duration (Seconds)DecimalIf a Pre Output is selected, set the duration to turn the Pre Output on for before every measurement is acquired.
Pre During MeasureBooleanCheck to turn the output off after (opposed to before) the measurement is complete
Enable HeaterBooleanEnable heater to evaporate condensation. Turn on heater x seconds every y measurements
Heater On Seconds (Seconds)Decimal - Default Value: 1.0How long to turn the heater on
Heater On PeriodInteger - Default Value: 10After how many measurements to turn the heater on. This will repeat

Sensirion: SHT4X~

OptionTypeDescription
I2C AddressTextThe address of the I2C device.
I2C BusIntegerThe Bus the I2C device is connected.
Measurements EnabledMulti-SelectThe measurements to record
Period (Seconds)DecimalThe duration between measurements or actions
Pre OutputSelectTurn the selected output on before taking every measurement
Pre Out Duration (Seconds)DecimalIf a Pre Output is selected, set the duration to turn the Pre Output on for before every measurement is acquired.
Pre During MeasureBooleanCheck to turn the output off after (opposed to before) the measurement is complete

Sensirion: SHTC3~

OptionTypeDescription
I2C AddressTextThe address of the I2C device.
I2C BusIntegerThe Bus the I2C device is connected.
Measurements EnabledMulti-SelectThe measurements to record
Period (Seconds)DecimalThe duration between measurements or actions
Pre OutputSelectTurn the selected output on before taking every measurement
Pre Out Duration (Seconds)DecimalIf a Pre Output is selected, set the duration to turn the Pre Output on for before every measurement is acquired.
Pre During MeasureBooleanCheck to turn the output off after (opposed to before) the measurement is complete

Sensorion: SHT31 Smart Gadget~

OptionTypeDescription
Bluetooth MAC (XX:XX:XX:XX:XX:XX)TextThe Hci location of the Bluetooth device.
Bluetooth Adapter (hci[X])TextThe adapter of the Bluetooth device.
Measurements EnabledMulti-SelectThe measurements to record
Period (Seconds)DecimalThe duration between measurements or actions
Pre OutputSelectTurn the selected output on before taking every measurement
Pre Out Duration (Seconds)DecimalIf a Pre Output is selected, set the duration to turn the Pre Output on for before every measurement is acquired.
Pre During MeasureBooleanCheck to turn the output off after (opposed to before) the measurement is complete
Download Stored DataBoolean - Default Value: TrueDownload the data logged to the device.
Set Logging Interval (Seconds)Integer - Default Value: 600Set the logging interval the device will store measurements on its internal memory.

Silicon Labs: SI1145~

  • Manufacturer: Silicon Labs
  • Measurements: Light (UV/Visible/IR), Proximity (cm)
  • Interfaces: I2C
  • Libraries: si1145
  • Dependencies: SI1145
  • Manufacturer URL: Link
  • Datasheet URL: Link
  • Product URL: Link
OptionTypeDescription
I2C AddressTextThe address of the I2C device.
I2C BusIntegerThe Bus the I2C device is connected.
Measurements EnabledMulti-SelectThe measurements to record
Period (Seconds)DecimalThe duration between measurements or actions
Pre OutputSelectTurn the selected output on before taking every measurement
Pre Out Duration (Seconds)DecimalIf a Pre Output is selected, set the duration to turn the Pre Output on for before every measurement is acquired.
Pre During MeasureBooleanCheck to turn the output off after (opposed to before) the measurement is complete

Silicon Labs: Si7021~

OptionTypeDescription
I2C AddressTextThe address of the I2C device.
I2C BusIntegerThe Bus the I2C device is connected.
Period (Seconds)DecimalThe duration between measurements or actions
Pre OutputSelectTurn the selected output on before taking every measurement
Pre Out Duration (Seconds)DecimalIf a Pre Output is selected, set the duration to turn the Pre Output on for before every measurement is acquired.
Pre During MeasureBooleanCheck to turn the output off after (opposed to before) the measurement is complete

Sonoff: TH16/10 (Tasmota firmware) with AM2301/Si7021~

  • Manufacturer: Sonoff
  • Measurements: Humidity/Temperature
  • Libraries: requests
  • Dependencies: requests
  • Manufacturer URL: Link

This Input module allows the use of any temperature/humidity sensor with the TH10/TH16. Changing the Sensor Name option changes the key that's queried from the returned dictionary of measurements. If you would like to use this module with a version of this device that uses the AM2301, change Sensor Name to AM2301.

OptionTypeDescription
Measurements EnabledMulti-SelectThe measurements to record
Period (Seconds)DecimalThe duration between measurements or actions
Pre OutputSelectTurn the selected output on before taking every measurement
Pre Out Duration (Seconds)DecimalIf a Pre Output is selected, set the duration to turn the Pre Output on for before every measurement is acquired.
Pre During MeasureBooleanCheck to turn the output off after (opposed to before) the measurement is complete
IP AddressText - Default Value: 192.168.0.100The IP address of the device
Sensor NameText - Default Value: SI7021The name of the sensor connected to the device (specific key name in the returned dictionary)

Sonoff: TH16/10 (Tasmota firmware) with AM2301~

  • Manufacturer: Sonoff
  • Measurements: Humidity/Temperature
  • Libraries: requests
  • Dependencies: requests
  • Manufacturer URL: Link
OptionTypeDescription
Measurements EnabledMulti-SelectThe measurements to record
Period (Seconds)DecimalThe duration between measurements or actions
Pre OutputSelectTurn the selected output on before taking every measurement
Pre Out Duration (Seconds)DecimalIf a Pre Output is selected, set the duration to turn the Pre Output on for before every measurement is acquired.
Pre During MeasureBooleanCheck to turn the output off after (opposed to before) the measurement is complete
IP AddressText - Default Value: 192.168.0.100The IP address of the device

Sonoff: TH16/10 (Tasmota firmware) with DS18B20~

  • Manufacturer: Sonoff
  • Measurements: Temperature
  • Libraries: requests
  • Dependencies: requests
  • Manufacturer URL: Link
OptionTypeDescription
Measurements EnabledMulti-SelectThe measurements to record
Period (Seconds)DecimalThe duration between measurements or actions
Pre OutputSelectTurn the selected output on before taking every measurement
Pre Out Duration (Seconds)DecimalIf a Pre Output is selected, set the duration to turn the Pre Output on for before every measurement is acquired.
Pre During MeasureBooleanCheck to turn the output off after (opposed to before) the measurement is complete
IP AddressText - Default Value: 192.168.0.100The IP address of the device

Stadia Maps: GL: Stadia Maps~

  • Manufacturer: Stadia Maps
  • Measurements: Status
  • Libraries: gis_stadia
  • Manufacturer URL: Link

고품질 디자인을 강조하는 Stadia Maps의 지도 서버입니다. Alidade Smooth, Dark, OSMBright 등 눈이 편안한 색감과 고품질 폰트가 적용된 깔끔한 레이아웃을 제공하여 전문가용 대시보드 제작에 유리합니다.

OptionTypeDescription
Stadia/Stamen API KeyText
Map Style

Statistics Korea: KO: SGIS (Statistics Korea)~

  • Manufacturer: Statistics Korea
  • Measurements: Status
  • Libraries: gis_sgis
  • Manufacturer URL: Link

대한민국 통계청(SGIS)에서 제공하는 통계 지리 정보 서비스입니다. 한국의 시군구별 인구, 가구, 사업체 등 다양한 통계 데이터를 공간적으로 분석하고 시각화하기 위한 최적의 국내 전용 서비스입니다.

OptionTypeDescription
SGIS Service ID (Consumer Key)Text
SGIS Security Key (Consumer Secret)Text
Data Configuration
Statistic SubjectSelect
Year (YYYY)Text
Target Admin Code (adm_cd)Text
VisualizationSelect

TE Connectivity: HTU21D (Adafruit_CircuitPython_HTU21D)~

OptionTypeDescription
I2C AddressTextThe address of the I2C device.
I2C BusIntegerThe Bus the I2C device is connected.
Measurements EnabledMulti-SelectThe measurements to record
Period (Seconds)DecimalThe duration between measurements or actions
Pre OutputSelectTurn the selected output on before taking every measurement
Pre Out Duration (Seconds)DecimalIf a Pre Output is selected, set the duration to turn the Pre Output on for before every measurement is acquired.
Pre During MeasureBooleanCheck to turn the output off after (opposed to before) the measurement is complete
Temperature OffsetDecimalThe temperature offset (degrees Celsius) to apply

TE Connectivity: HTU21D (pigpio)~

  • Manufacturer: TE Connectivity
  • Measurements: Humidity/Temperature
  • Interfaces: I2C
  • Libraries: pigpio
  • Dependencies: pigpio, pigpio
  • Manufacturer URL: Link
  • Datasheet URL: Link
  • Product URL: Link
OptionTypeDescription
I2C AddressTextThe address of the I2C device.
I2C BusIntegerThe Bus the I2C device is connected.
Measurements EnabledMulti-SelectThe measurements to record
Period (Seconds)DecimalThe duration between measurements or actions
Pre OutputSelectTurn the selected output on before taking every measurement
Pre Out Duration (Seconds)DecimalIf a Pre Output is selected, set the duration to turn the Pre Output on for before every measurement is acquired.
Pre During MeasureBooleanCheck to turn the output off after (opposed to before) the measurement is complete
  • Manufacturer: TP-Link
  • Measurements: kilowatt hours
  • Interfaces: IP
  • Libraries: python-kasa
  • Dependencies: python-kasa, aio_msgpack_rpc
  • Manufacturer URL: Link

This measures from several Kasa power devices (plugs/strips) capable of measuring energy consumption. These include, but are not limited to the KP115 and HS600.

OptionTypeDescription
Measurements EnabledMulti-SelectThe measurements to record
Period (Seconds)DecimalThe duration between measurements or actions
Pre OutputSelectTurn the selected output on before taking every measurement
Pre Out Duration (Seconds)DecimalIf a Pre Output is selected, set the duration to turn the Pre Output on for before every measurement is acquired.
Pre During MeasureBooleanCheck to turn the output off after (opposed to before) the measurement is complete
Device TypeSelectThe type of Kasa device
HostText - Default Value: 0.0.0.0Host or IP address
Asyncio RPC PortInteger - Default Value: 18063The port to start the asyncio RPC server. Must be unique from other Kasa Outputs.
Commands
The total kWh can be cleared with the following button or with the Clear Total kWh Function Action. This will also clear all energy stats on the device, not just the total kWh.
Clear Total: Kilowatt-hourButton

Tasmota: Tasmota Outlet Energy Monitor (HTTP)~

  • Manufacturer: Tasmota
  • Measurements: Total Energy, Amps, Watts
  • Interfaces: HTTP
  • Libraries: requests
  • Manufacturer URL: Link
  • Product URL: Link

This input queries the energy usage information from a WiFi outlet that is running the tasmota firmware. There are many WiFi outlets that support tasmota, and many of of those have energy monitoring capabilities. When used with an MQTT Output, you can both control your tasmota outlets as well as mionitor their energy usage.

OptionTypeDescription
Measurements EnabledMulti-SelectThe measurements to record
Period (Seconds)DecimalThe duration between measurements or actions
Pre OutputSelectTurn the selected output on before taking every measurement
Pre Out Duration (Seconds)DecimalIf a Pre Output is selected, set the duration to turn the Pre Output on for before every measurement is acquired.
Pre During MeasureBooleanCheck to turn the output off after (opposed to before) the measurement is complete
HostText - Default Value: 192.168.0.50Host or IP address

Texas Instruments: ADS1015~

OptionTypeDescription
I2C AddressTextThe address of the I2C device.
I2C BusIntegerThe Bus the I2C device is connected.
Measurements EnabledMulti-SelectThe measurements to record
Period (Seconds)DecimalThe duration between measurements or actions
Pre OutputSelectTurn the selected output on before taking every measurement
Pre Out Duration (Seconds)DecimalIf a Pre Output is selected, set the duration to turn the Pre Output on for before every measurement is acquired.
Pre During MeasureBooleanCheck to turn the output off after (opposed to before) the measurement is complete
Measurements to AverageInteger - Default Value: 5The number of times to measure each channel. An average of the measurements will be stored.

Texas Instruments: ADS1115: Generic Analog pH/EC~

This input relies on an ADS1115 analog-to-digital converter (ADC) to measure pH and/or electrical conductivity (EC) from analog sensors. You can enable or disable either measurement if you want to only connect a pH sensor or an EC sensor by selecting which measurements you want to under Measurements Enabled. Select which channel each sensor is connected to on the ADC. There are default calibration values initially set for the Input. There are also functions to allow you to easily calibrate your sensors with calibration solutions. If you use the Calibrate Slot actions, these values will be calculated and will replace the currently-set values. You can use the Clear Calibration action to delete the database values and return to using the default values. If you delete the Input or create a new Input to use your ADC/sensors with, you will need to recalibrate in order to store new calibration data.

OptionTypeDescription
I2C AddressTextThe address of the I2C device.
I2C BusIntegerThe Bus the I2C device is connected.
Measurements EnabledMulti-SelectThe measurements to record
Period (Seconds)DecimalThe duration between measurements or actions
Pre OutputSelectTurn the selected output on before taking every measurement
Pre Out Duration (Seconds)DecimalIf a Pre Output is selected, set the duration to turn the Pre Output on for before every measurement is acquired.
Pre During MeasureBooleanCheck to turn the output off after (opposed to before) the measurement is complete
ADC Channel: pHSelect(Options: [Channel 0 | Channel 1 | Channel 2 | Channel 3] (Default in bold)The ADC channel the pH sensor is connected
ADC Channel: ECSelect(Options: [Channel 0 | Channel 1 | Channel 2 | Channel 3] (Default in bold)The ADC channel the EC sensor is connected
Temperature Compensation
Temperature Compensation: MeasurementSelect Measurement (Input, Function)Select a measurement for temperature compensation
Temperature Compensation: Max Age (Seconds)Integer - Default Value: 120The maximum age of the measurement to use
pH Calibration Data
Cal data: V1 (internal)Decimal - Default Value: 1.5Calibration data: Voltage
Cal data: pH1 (internal)Decimal - Default Value: 7.0Calibration data: pH
Cal data: T1 (internal)Decimal - Default Value: 25.0Calibration data: Temperature
Cal data: V2 (internal)Decimal - Default Value: 2.032Calibration data: Voltage
Cal data: pH2 (internal)Decimal - Default Value: 4.0Calibration data: pH
Cal data: T2 (internal)Decimal - Default Value: 25.0Calibration data: Temperature
EC Calibration Data
EC cal data: V1 (internal)Decimal - Default Value: 0.232EC calibration data: Voltage
EC cal data: EC1 (internal)Decimal - Default Value: 1413.0EC calibration data: EC
EC cal data: T1 (internal)Decimal - Default Value: 25.0EC calibration data: EC
EC cal data: V2 (internal)Decimal - Default Value: 2.112EC calibration data: Voltage
EC cal data: EC2 (internal)Decimal - Default Value: 12880.0EC calibration data: EC
EC cal data: T2 (internal)Decimal - Default Value: 25.0EC calibration data: EC
Commands
pH Calibration Actions: Place your probe in a solution of known pH. Set the known pH value in the "Calibration buffer pH" field, and press "Calibrate pH, slot 1". Repeat with a second buffer, and press "Calibrate pH, slot 2". You don't need to change the values under "Custom Options".
Calibration buffer pHDecimal - Default Value: 7.0This is the nominal pH of the calibration buffer, usually labelled on the bottle.
Calibrate pH, slot 1Button
Calibrate pH, slot 2Button
Clear pH Calibration SlotsButton
EC Calibration Actions: Place your probe in a solution of known EC. Set the known EC value in the "Calibration standard EC" field, and press "Calibrate EC, slot 1". Repeat with a second standard, and press "Calibrate EC, slot 2". You don't need to change the values under "Custom Options".
Calibration standard ECDecimal - Default Value: 1413.0This is the nominal EC of the calibration standard, usually labelled on the bottle.
Calibrate EC, slot 1Button
Calibrate EC, slot 2Button
Clear EC Calibration SlotsButton

Texas Instruments: ADS1115~

OptionTypeDescription
I2C AddressTextThe address of the I2C device.
I2C BusIntegerThe Bus the I2C device is connected.
Measurements EnabledMulti-SelectThe measurements to record
Period (Seconds)DecimalThe duration between measurements or actions
Pre OutputSelectTurn the selected output on before taking every measurement
Pre Out Duration (Seconds)DecimalIf a Pre Output is selected, set the duration to turn the Pre Output on for before every measurement is acquired.
Pre During MeasureBooleanCheck to turn the output off after (opposed to before) the measurement is complete
Measurements to AverageInteger - Default Value: 5The number of times to measure each channel. An average of the measurements will be stored.

Texas Instruments: ADS1256: Generic Analog pH/EC~

  • Manufacturer: Texas Instruments
  • Measurements: Ion Concentration/Electrical Conductivity
  • Interfaces: UART
  • Libraries: wiringpi, aot-inc/PiPyADC-py3
  • Dependencies: wiringpi, pipyadc_py3

This input relies on an ADS1256 analog-to-digital converter (ADC) to measure pH and/or electrical conductivity (EC) from analog sensors. You can enable or disable either measurement if you want to only connect a pH sensor or an EC sensor by selecting which measurements you want to under Measurements Enabled. Select which channel each sensor is connected to on the ADC. There are default calibration values initially set for the Input. There are also functions to allow you to easily calibrate your sensors with calibration solutions. If you use the Calibrate Slot actions, these values will be calculated and will replace the currently-set values. You can use the Clear Calibration action to delete the database values and return to using the default values. If you delete the Input or create a new Input to use your ADC/sensors with, you will need to recalibrate in order to store new calibration data.

OptionTypeDescription
Measurements EnabledMulti-SelectThe measurements to record
Period (Seconds)DecimalThe duration between measurements or actions
Pre OutputSelectTurn the selected output on before taking every measurement
Pre Out Duration (Seconds)DecimalIf a Pre Output is selected, set the duration to turn the Pre Output on for before every measurement is acquired.
Pre During MeasureBooleanCheck to turn the output off after (opposed to before) the measurement is complete
ADC Channel: pHSelect(Options: [Not Connected | Channel 0 | Channel 1 | Channel 2 | Channel 3 | Channel 4 | Channel 5 | Channel 6 | Channel 7] (Default in bold)The ADC channel the pH sensor is connected
ADC Channel: ECSelect(Options: [Not Connected | Channel 0 | Channel 1 | Channel 2 | Channel 3 | Channel 4 | Channel 5 | Channel 6 | Channel 7] (Default in bold)The ADC channel the EC sensor is connected
Temperature Compensation
Temperature Compensation: MeasurementSelect Measurement (Input, Function)Select a measurement for temperature compensation
Temperature Compensation: Max Age (Seconds)Integer - Default Value: 120The maximum age of the measurement to use
pH Calibration Data
Cal data: V1 (internal)Decimal - Default Value: 1.5Calibration data: Voltage
Cal data: pH1 (internal)Decimal - Default Value: 7.0Calibration data: pH
Cal data: T1 (internal)Decimal - Default Value: 25.0Calibration data: Temperature
Cal data: V2 (internal)Decimal - Default Value: 2.032Calibration data: Voltage
Cal data: pH2 (internal)Decimal - Default Value: 4.0Calibration data: pH
Cal data: T2 (internal)Decimal - Default Value: 25.0Calibration data: Temperature
EC Calibration Data
EC cal data: V1 (internal)Decimal - Default Value: 0.232EC calibration data: Voltage
EC cal data: EC1 (internal)Decimal - Default Value: 1413.0EC calibration data: EC
EC cal data: T1 (internal)Decimal - Default Value: 25.0EC calibration data: EC
EC cal data: V2 (internal)Decimal - Default Value: 2.112EC calibration data: Voltage
EC cal data: EC2 (internal)Decimal - Default Value: 12880.0EC calibration data: EC
EC cal data: T2 (internal)Decimal - Default Value: 25.0EC calibration data: EC
CalibrationSelectSet the calibration method to perform during Input activation
Commands
pH Calibration Actions: Place your probe in a solution of known pH. Set the known pH value in the `Calibration buffer pH` field, and press `Calibrate pH, slot 1`. Repeat with a second buffer, and press `Calibrate pH, slot 2`. You don't need to change the values under `Custom Options`.
Calibration buffer pHDecimal - Default Value: 7.0This is the nominal pH of the calibration buffer, usually labelled on the bottle.
Calibrate pH, slot 1Button
Calibrate pH, slot 2Button
Clear pH Calibration SlotsButton
EC Calibration Actions: Place your probe in a solution of known EC. Set the known EC value in the `Calibration standard EC` field, and press `Calibrate EC, slot 1`. Repeat with a second standard, and press `Calibrate EC, slot 2`. You don't need to change the values under `Custom Options`.
Calibration standard ECDecimal - Default Value: 1413.0This is the nominal EC of the calibration standard, usually labelled on the bottle.
Calibrate EC, slot 1Button
Calibrate EC, slot 2Button
Clear EC Calibration SlotsButton

Texas Instruments: ADS1256~

  • Manufacturer: Texas Instruments
  • Measurements: Voltage (Waveshare, Analog-to-Digital Converter)
  • Interfaces: UART
  • Libraries: wiringpi, aot-inc/PiPyADC-py3
  • Dependencies: wiringpi, pipyadc_py3
OptionTypeDescription
Measurements EnabledMulti-SelectThe measurements to record
Period (Seconds)DecimalThe duration between measurements or actions
Pre OutputSelectTurn the selected output on before taking every measurement
Pre Out Duration (Seconds)DecimalIf a Pre Output is selected, set the duration to turn the Pre Output on for before every measurement is acquired.
Pre During MeasureBooleanCheck to turn the output off after (opposed to before) the measurement is complete
CalibrationSelectSet the calibration method to perform during Input activation

Texas Instruments: ADS1x15~

  • Manufacturer: Texas Instruments
  • Measurements: Voltage (Analog-to-Digital Converter)
  • Interfaces: I2C
  • Libraries: Adafruit_ADS1x15 [DEPRECATED]
  • Dependencies: Adafruit-GPIO, Adafruit-ADS1x15

The Adafruit_ADS1x15 is deprecated. It's advised to use The Circuit Python ADS1x15 Input.

OptionTypeDescription
I2C AddressTextThe address of the I2C device.
I2C BusIntegerThe Bus the I2C device is connected.
Measurements EnabledMulti-SelectThe measurements to record
Period (Seconds)DecimalThe duration between measurements or actions
Pre OutputSelectTurn the selected output on before taking every measurement
Pre Out Duration (Seconds)DecimalIf a Pre Output is selected, set the duration to turn the Pre Output on for before every measurement is acquired.
Pre During MeasureBooleanCheck to turn the output off after (opposed to before) the measurement is complete
Measurements to AverageInteger - Default Value: 5The number of times to measure each channel. An average of the measurements will be stored.

Texas Instruments: HDC1000~

  • Manufacturer: Texas Instruments
  • Measurements: Humidity/Temperature
  • Interfaces: I2C
  • Libraries: fcntl/io
  • Manufacturer URL: Link
  • Datasheet URL: Link
OptionTypeDescription
I2C AddressTextThe address of the I2C device.
I2C BusIntegerThe Bus the I2C device is connected.
Measurements EnabledMulti-SelectThe measurements to record
Period (Seconds)DecimalThe duration between measurements or actions
Pre OutputSelectTurn the selected output on before taking every measurement
Pre Out Duration (Seconds)DecimalIf a Pre Output is selected, set the duration to turn the Pre Output on for before every measurement is acquired.
Pre During MeasureBooleanCheck to turn the output off after (opposed to before) the measurement is complete

Texas Instruments: INA219x~

OptionTypeDescription
I2C AddressTextThe address of the I2C device.
I2C BusIntegerThe Bus the I2C device is connected.
Measurements EnabledMulti-SelectThe measurements to record
Period (Seconds)DecimalThe duration between measurements or actions
Pre OutputSelectTurn the selected output on before taking every measurement
Pre Out Duration (Seconds)DecimalIf a Pre Output is selected, set the duration to turn the Pre Output on for before every measurement is acquired.
Pre During MeasureBooleanCheck to turn the output off after (opposed to before) the measurement is complete
Measurements to AverageInteger - Default Value: 5The number of times to measure each channel. An average of the measurements will be stored.
Calibration RangeSelect(Options: [32V @ 2A max (default) | 32V @ 1A max | 16V @ 400mA max | 16V @ 5A max] (Default in bold)Set the device calibration range
Bus Voltage RangeSelect(Options: [(0x00) - 16V | (0x01) - 32V (default)] (Default in bold)Set the bus voltage range
Bus ADC ResolutionSelect(Options: [(0x00) - 9 Bit / 1 Sample | (0x01) - 10 Bit / 1 Sample | (0x02) - 11 Bit / 1 Sample | (0x03) - 12 Bit / 1 Sample (default) | (0x09) - 12 Bit / 2 Samples | (0x0A) - 12 Bit / 4 Samples | (0x0B) - 12 Bit / 8 Samples | (0x0C) - 12 Bit / 16 Samples | (0x0D) - 12 Bit / 32 Samples | (0x0E) - 12 Bit / 64 Samples | (0x0F) - 12 Bit / 128 Samples] (Default in bold)Set the Bus ADC Resolution.
Shunt ADC ResolutionSelect(Options: [(0x00) - 9 Bit / 1 Sample | (0x01) - 10 Bit / 1 Sample | (0x02) - 11 Bit / 1 Sample | (0x03) - 12 Bit / 1 Sample (default) | (0x09) - 12 Bit / 2 Samples | (0x0A) - 12 Bit / 4 Samples | (0x0B) - 12 Bit / 8 Samples | (0x0C) - 12 Bit / 16 Samples | (0x0D) - 12 Bit / 32 Samples | (0x0E) - 12 Bit / 64 Samples | (0x0F) - 12 Bit / 128 Samples] (Default in bold)Set the Shunt ADC Resolution.

Texas Instruments: TMP006~

  • Manufacturer: Texas Instruments
  • Measurements: Temperature (Object/Die)
  • Interfaces: I2C
  • Libraries: Adafruit_TMP
  • Dependencies: Adafruit-TMP
  • Datasheet URL: Link
  • Product URL: Link
OptionTypeDescription
I2C AddressTextThe address of the I2C device.
I2C BusIntegerThe Bus the I2C device is connected.
Measurements EnabledMulti-SelectThe measurements to record
Period (Seconds)DecimalThe duration between measurements or actions
Pre OutputSelectTurn the selected output on before taking every measurement
Pre Out Duration (Seconds)DecimalIf a Pre Output is selected, set the duration to turn the Pre Output on for before every measurement is acquired.
Pre During MeasureBooleanCheck to turn the output off after (opposed to before) the measurement is complete

The Things Network: The Things Network: Data Storage (TTN v2)~

  • Manufacturer: The Things Network
  • Measurements: Variable measurements
  • Libraries: requests
  • Dependencies: requests

This Input receives and stores measurements from the Data Storage Integration on The Things Network.

OptionTypeDescription
Measurements EnabledMulti-SelectThe measurements to record
Period (Seconds)DecimalThe duration between measurements or actions
Start Offset (Seconds)IntegerThe duration to wait before the first operation
Pre OutputSelectTurn the selected output on before taking every measurement
Pre Out Duration (Seconds)DecimalIf a Pre Output is selected, set the duration to turn the Pre Output on for before every measurement is acquired.
Pre During MeasureBooleanCheck to turn the output off after (opposed to before) the measurement is complete
Application IDTextThe Things Network Application ID
App API KeyTextThe Things Network Application API Key
Device IDTextThe Things Network Device ID
Channel Options
NameTextA name to distinguish this from others
Variable NameTextThe TTN variable name

The Things Network: The Things Network: Data Storage (TTN v3, Payload Key)~

  • Manufacturer: The Things Network
  • Measurements: Variable measurements
  • Libraries: requests
  • Dependencies: requests

This Input receives and stores measurements from the Data Storage Integration on The Things Network. If you have key/value pairs as your payload, enter the key name in Variable Name and the corresponding value for that key will be stored in the measurement database.

OptionTypeDescription
Measurements EnabledMulti-SelectThe measurements to record
Period (Seconds)DecimalThe duration between measurements or actions
Start Offset (Seconds)IntegerThe duration to wait before the first operation
Pre OutputSelectTurn the selected output on before taking every measurement
Pre Out Duration (Seconds)DecimalIf a Pre Output is selected, set the duration to turn the Pre Output on for before every measurement is acquired.
Pre During MeasureBooleanCheck to turn the output off after (opposed to before) the measurement is complete
Application IDTextThe Things Network Application ID
App API KeyTextThe Things Network Application API Key
Device IDTextThe Things Network Device ID
Channel Options
NameTextA name to distinguish this from others
Variable NameTextThe TTN variable name

The Things Network: The Things Network: Data Storage (TTN v3, Payload jmespath Expression)~

  • Manufacturer: The Things Network
  • Measurements: Variable measurements
  • Libraries: requests, jmespath
  • Dependencies: requests, jmespath

This Input receives and stores measurements from the Data Storage Integration on The Things Network. The given Payload jmespath Expression is used as a JMESPATH expression to find the corresponding value that will be stored for that channel. Be sure you select and save the Measurement Unit for each channel. Once the unit has been saved, you can convert to other units in the Convert Measurement section. Example expressions for jmespath (https://jmespath.org) include temperature, sensors[0].temperature, and bathroom.temperature which refer to the temperature as a direct key within the first entry of sensors or as a subkey of bathroom, respectively. Jmespath elements and keys that contain special characters have to be enclosed in double quotes, e.g. "sensor-1".temperature.

OptionTypeDescription
Measurements EnabledMulti-SelectThe measurements to record
Period (Seconds)DecimalThe duration between measurements or actions
Start Offset (Seconds)IntegerThe duration to wait before the first operation
Pre OutputSelectTurn the selected output on before taking every measurement
Pre Out Duration (Seconds)DecimalIf a Pre Output is selected, set the duration to turn the Pre Output on for before every measurement is acquired.
Pre During MeasureBooleanCheck to turn the output off after (opposed to before) the measurement is complete
Application IDTextThe Things Network Application ID
App API KeyTextThe Things Network Application API Key
Device IDTextThe Things Network Device ID
Channel Options
NameTextA name to distinguish this from others
Payload jmespath ExpressionTextThe TTN jmespath expression to return the value to store

Thunderforest: GL: Thunderforest~

  • Manufacturer: Thunderforest
  • Measurements: Status
  • Libraries: gis_thunderforest
  • Manufacturer URL: Link

OpenStreetMap 데이터를 활용하여 특정 목적에 맞춘 독창적인 테마 지도를 제공합니다. 자전거 도로(Cycle), 대중교통(Transport), 밤 지도, 거친 풍경 등 시각적으로 강렬한 고유 스타일을 경험할 수 있습니다.

OptionTypeDescription
Thunderforest API KeyText
Map Style

Vworld: KO: Vworld~

  • Manufacturer: Vworld
  • Measurements: Status
  • Libraries: gis_vworld
  • Manufacturer URL: Link

대한민국 국토교통부의 공간정보 오픈플랫폼 브이월드 서비스입니다. 국내에서 가장 정밀한 국가 고해상도 항공 사진과 수치 지도, 지적도, 실시간 교통량 등을 제공하며 국내 업무 지원에 가장 특화된 국가 국가표준 지도입니다.

OptionTypeDescription
API KeyText
등록 도메인Text
Map Layer / Style
범례 보기Boolean

Winsen: MH-Z14A~

  • Manufacturer: Winsen
  • Measurements: CO2
  • Interfaces: UART
  • Libraries: serial
  • Dependencies: RPi.GPIO
  • Manufacturer URL: Link
  • Datasheet URL: Link
OptionTypeDescription
UART DeviceTextThe UART device location (e.g. /dev/ttyUSB1)
Period (Seconds)DecimalThe duration between measurements or actions
Pre OutputSelectTurn the selected output on before taking every measurement
Pre Out Duration (Seconds)DecimalIf a Pre Output is selected, set the duration to turn the Pre Output on for before every measurement is acquired.
Pre During MeasureBooleanCheck to turn the output off after (opposed to before) the measurement is complete
Automatic Self-calibrationBoolean - Default Value: TrueEnable automatic self-calibration
Measurement RangeSelect(Options: [400 - 2000 ppmv | 400 - 5000 ppmv | 400 - 10000 ppmv] (Default in bold)Set the measuring range of the sensor
The CO2 measurement can also be obtained using PWM via a GPIO pin. Enter the pin number below or leave blank to disable this option. This also makes it possible to obtain measurements even if the UART interface is not available (note that the sensor can't be configured / calibrated without a working UART interface).
GPIO OverrideTextObtain readings using PWM on this GPIO pin instead of via UART
Commands
Calibrate Zero PointButton
Span Point (ppmv)Integer - Default Value: 2000The ppmv concentration for a span point calibration
Calibrate Span PointButton

Winsen: MH-Z16~

  • Manufacturer: Winsen
  • Measurements: CO2
  • Interfaces: UART, I2C
  • Libraries: smbus2/serial
  • Dependencies: smbus2
  • Manufacturer URL: Link
  • Datasheet URL: Link
OptionTypeDescription
I2C AddressTextThe address of the I2C device.
I2C BusIntegerThe Bus the I2C device is connected.
UART DeviceTextThe UART device location (e.g. /dev/ttyUSB1)
Period (Seconds)DecimalThe duration between measurements or actions
Pre OutputSelectTurn the selected output on before taking every measurement
Pre Out Duration (Seconds)DecimalIf a Pre Output is selected, set the duration to turn the Pre Output on for before every measurement is acquired.
Pre During MeasureBooleanCheck to turn the output off after (opposed to before) the measurement is complete

Winsen: MH-Z19~

  • Manufacturer: Winsen
  • Measurements: CO2
  • Interfaces: UART
  • Libraries: serial
  • Datasheet URL: Link

This is the version of the sensor that does not include the ability to conduct automatic baseline correction (ABC). See the B version of the sensor if you wish to use ABC.

OptionTypeDescription
UART DeviceTextThe UART device location (e.g. /dev/ttyUSB1)
Period (Seconds)DecimalThe duration between measurements or actions
Pre OutputSelectTurn the selected output on before taking every measurement
Pre Out Duration (Seconds)DecimalIf a Pre Output is selected, set the duration to turn the Pre Output on for before every measurement is acquired.
Pre During MeasureBooleanCheck to turn the output off after (opposed to before) the measurement is complete
Measurement RangeSelect(Options: [0 - 1000 ppmv | 0 - 2000 ppmv | 0 - 3000 ppmv | 0 - 5000 ppmv] (Default in bold)Set the measuring range of the sensor
Commands
Calibrate Zero PointButton
Span Point (ppmv)Integer - Default Value: 2000The ppmv concentration for a span point calibration
Calibrate Span PointButton

Winsen: MH-Z19B~

  • Manufacturer: Winsen
  • Measurements: CO2
  • Interfaces: UART
  • Libraries: serial
  • Manufacturer URL: Link
  • Datasheet URL: Link

This is the B version of the sensor that includes the ability to conduct automatic baseline correction (ABC).

OptionTypeDescription
UART DeviceTextThe UART device location (e.g. /dev/ttyUSB1)
Period (Seconds)DecimalThe duration between measurements or actions
Pre OutputSelectTurn the selected output on before taking every measurement
Pre Out Duration (Seconds)DecimalIf a Pre Output is selected, set the duration to turn the Pre Output on for before every measurement is acquired.
Pre During MeasureBooleanCheck to turn the output off after (opposed to before) the measurement is complete
Automatic Baseline CorrectionBooleanEnable automatic baseline correction (ABC)
Measurement RangeSelect(Options: [0 - 1000 ppmv | 0 - 2000 ppmv | 0 - 3000 ppmv | 0 - 5000 ppmv | 0 - 10000 ppmv] (Default in bold)Set the measuring range of the sensor
Commands
Calibrate Zero PointButton
Span Point (ppmv)Integer - Default Value: 2000The ppmv concentration for a span point calibration
Calibrate Span PointButton

Winsen: ZH03B~

  • Manufacturer: Winsen
  • Measurements: Particulates
  • Interfaces: UART
  • Libraries: serial
  • Manufacturer URL: Link
  • Datasheet URL: Link
OptionTypeDescription
UART DeviceTextThe UART device location (e.g. /dev/ttyUSB1)
Measurements EnabledMulti-SelectThe measurements to record
Period (Seconds)DecimalThe duration between measurements or actions
Pre OutputSelectTurn the selected output on before taking every measurement
Pre Out Duration (Seconds)DecimalIf a Pre Output is selected, set the duration to turn the Pre Output on for before every measurement is acquired.
Pre During MeasureBooleanCheck to turn the output off after (opposed to before) the measurement is complete
Fan Off After MeasureBooleanTurn the fan on only during the measurement
Fan On Duration (Seconds)Decimal - Default Value: 50.0How long to turn the fan on before acquiring measurements
Number of MeasurementsInteger - Default Value: 3How many measurements to acquire. If more than 1 are acquired that are less than 1001, the average of the measurements will be stored.

Xiaomi: Miflora~

  • Manufacturer: Xiaomi
  • Measurements: EC/Light/Moisture/Temperature
  • Interfaces: BT
  • Libraries: miflora
  • Dependencies: libglib2.0-dev, miflora, bluepy
OptionTypeDescription
Bluetooth MAC (XX:XX:XX:XX:XX:XX)TextThe Hci location of the Bluetooth device.
Bluetooth Adapter (hci[X])TextThe adapter of the Bluetooth device.
Measurements EnabledMulti-SelectThe measurements to record
Period (Seconds)DecimalThe duration between measurements or actions
Pre OutputSelectTurn the selected output on before taking every measurement
Pre Out Duration (Seconds)DecimalIf a Pre Output is selected, set the duration to turn the Pre Output on for before every measurement is acquired.
Pre During MeasureBooleanCheck to turn the output off after (opposed to before) the measurement is complete

Xiaomi: Mijia LYWSD03MMC (ATC and non-ATC modes)~

More information about ATC mode can be found at https://github.com/JsBergbau/MiTemperature2

OptionTypeDescription
Bluetooth MAC (XX:XX:XX:XX:XX:XX)TextThe Hci location of the Bluetooth device.
Bluetooth Adapter (hci[X])TextThe adapter of the Bluetooth device.
Measurements EnabledMulti-SelectThe measurements to record
Period (Seconds)DecimalThe duration between measurements or actions
Pre OutputSelectTurn the selected output on before taking every measurement
Pre Out Duration (Seconds)DecimalIf a Pre Output is selected, set the duration to turn the Pre Output on for before every measurement is acquired.
Pre During MeasureBooleanCheck to turn the output off after (opposed to before) the measurement is complete
Enable ATC ModeBooleanEnable sensor ATC mode

ams: AS7341~

OptionTypeDescription
I2C AddressTextThe address of the I2C device.
I2C BusIntegerThe Bus the I2C device is connected.
Period (Seconds)DecimalThe duration between measurements or actions
Pre OutputSelectTurn the selected output on before taking every measurement
Pre Out Duration (Seconds)DecimalIf a Pre Output is selected, set the duration to turn the Pre Output on for before every measurement is acquired.
Pre During MeasureBooleanCheck to turn the output off after (opposed to before) the measurement is complete